background image

1

ZCE831 

Date 2019May7/D

 

IMPACT WRENCH SAFETY

Impact wrenches can cause flying particles.

Proper eye protection must be worn at all times by tool user and bystanders.

Flying particles can cause eye injury.

Sockets, bits and adapters not made for power tools can break when used with power tools. Sockets, bits and adapters not made for 

impact wrenches can break when used with impact wrenches.

Proper eye protection must be worn at all times by tool user and bystanders. Use only impact sockets, bits and adapters that are 
in good condition. Keep hands away from sockets, bits and adapters.

Broken sockets, bits and adapters can cause injury.

Power tools generate noise.

Ear protection must be worn when tool noise level exceeds 85 dBA. We also recommend that ear protection be worn when the 
tool noise level is below 85 dBA. See the tool’s information sheet for the noise level.

Prolonged exposure to noise can cause hearing loss.

Power tools vibrate.

Excessive vibration can cause injury. If numbness, tingling, pain or whitening of the skin occurs, stop using tool and consult a 
physician. See the tool’s information sheet for the vibration level.

Prolonged exposure to vibration can cause injury.

Worn, chipped, or cracked sockets, bits, and adapters can break.

Do not use worn, chipped, or cracked sockets, bits, or adapters.

Broken sockets, bits and adapters can cause injury.

Impact wrenches present  a risk of entanglement.

Keep loose hair away from power tools and accessories. Keep hands away from moving parts of the tool and accessories. Do 
not wear jewelry, loose clothing, or neckwear around power tools. Keep work area clear of cleaning rags and all items that could 
become entangled with the tool.

Entanglements can cause injuries.

Driving screws creates dust.

Do not breathe dust created when driving screws. Use approved mask.  Some dust created by power sanding, sawing, grinding,
drilling, and other construction activities contains chemicals known to cause cancer, birth defects and other reproductive harm.

Breathing dust created when driving screws can cause injury.

This tool is not insulated for contact with electric power sources.

Do not use near live electric circuits. When driving screws into walls, be aware that they may have hidden electric wires.

Electric shock can cause injury.

This tool is not intended for use in a flammable or explosive atmosphere.

Do not use this tool in a flammable or explosive atmosphere.

Explosions and fire can cause injury.

Sudden and unexpected tool movement can occur when the fastener bottoms on the work.

Be sure your body position allows you to have control of the tool at all times. Make sure your footing is secure. Consult 
manufacturer for proper reaction bar if movement is excessive.
When using a reaction bar:
•  Be aware hands or feet can be injured if bar breaks.
•  Keep hands from between bar and workpiece. When operating the tool, always keep the body and particularly the hands away 

from the working attachment fixed to the tool. Hands and fingers can be injured if caught between bar and work piece.

•  Follow instructions supplied with reaction bar for proper installation and use.
If the tool appears to malfunction, remove from use immediately and arrange for service and repair. If it is not practical to remove tool 
from service, then shut off the air supply to the tool and write or have written a warning note and attach it to the tool.
Always when using the tool, adopt a firm footing and/or position and grip the tool sufficiently only to overcome any reaction 
forces that may result from the tool doing work. Do not overgrip.
Never lay the tool down until the working attachment has stopped moving.

Sudden and unexpected tool movement can cause injury.

Form ZCE831

Date 2019May7/D

Page 1 of 34

SAVE THESE INSTRUCTIONS!

Read and understand these instructions before operating this tool.

INSTRUCTIONS & PARTS LIST FOR IW1000MP IMPACT WRENCH

SERIAL“A”

WARNING

When used improperly power tools can create hazardous situations.

Everyone using, maintaining, changing accessories or working near this tool must read, understand and follow these Safety Instructions!

Improperly used power tools can cause injury or death.

250 Snap-on Drive • PO Box 1596 • Murphy, NC  28906 • USA • Phone: 828-835-9765 •www.siouxtools.com

Original  
Instructions

Summary of Contents for IW1000MP

Page 1: ...g screws can cause injury This tool is not insulated for contact with electric power sources Do not use near live electric circuits When driving screws into walls be aware that they may have hidden el...

Page 2: ...oses that are not oil resistant or are not rated for the working pressure can burst Make sure that all air hoses are oil resistant and rated for the working pressure Air hoses that burst can cause inj...

Page 3: ...ditional one quarter to one half turn slight additional turning is necessary if gaskets are being clamped For additional power needed on disassembly work turn regulator to its fully open position This...

Page 4: ...ing long nose pliers Using a hammer and a punch remove Spring Pin 10 and remove Inside Trigger 12 Remove Screw 15 with a screw driver and remove Spring 14 and Steel Ball 13 from the detent hole in the...

Page 5: ...taub erzeugt Atmen Sie den Staub nicht ein Tragen Sie eine zugelassene Staubmaske Durch Maschinenschleifen S gen Schleifen Bohren und andereT tigkeiten auf Baustellen kann Staub mit Chemikalien freige...

Page 6: ...d leicht zug nglich sein um die Luftzufuhr im Notfall abstellen zu k nnen Peitschende Luftschl uche k nnen Verletzungen verursachen Luftschl uche die nicht lbest ndig bzw nicht f r den Betriebsdruck z...

Page 7: ...weitere bis Drehung festziehen Bei ebenfalls festzuziehenden Dichtungen noch etwas mehr festziehen Falls beim Auseinanderbauen zus tzliche Leistung ben tigt wird den Regler ganz auf ge ffnete Position...

Page 8: ...tte 22 aus dem Motorgeh use dr cken Anschlie end auch den Zylinder 25 aus dem Motorgeh use herausdr cken Den Schlauchadapter 1 vom Startergriff abziehen und Starterfeder 4 Ventilkugel 5 und Ventilstif...

Page 9: ...durante las operaciones de lijar aserrar amolar taladrar y en otras actividades de construcci n contienen substancias qu micas que se sabe causan c ncer defectos cong nitos y otros da os en el sistem...

Page 10: ...aceite o que no est n calibradas para la presi n que implica el trabajo pueden romperse violentamente Aseg rese de que todas las mangueras sean resistentes al aceite y que est n calibradas para sopor...

Page 11: ...la tuerca hasta que est al ras y luego apri tela de un cuarto a media vuelta m s un giro ligeramente mayor ser necesario si se est n apretando juntas o empaques Cuando se necesite una potencia adicio...

Page 12: ...e el cilindro 25 Retire el adaptador de la manguera 1 de la palanca reguladora y quite el resorte regulador 4 la esfera de la v lvula 5 y la clavija de la v lvula 6 de la palanca con unos alicates de...

Page 13: ...vvitamento Usare una maschera di tipo approvato La polvere generata durante le operazioni di levigatura di taglio di perforazione e varie altre attivit di costruzione contiene sostanze chimiche che po...

Page 14: ...r la pressione di servizio Tubi dell aria che scoppiano possono causare infortuni Il mancato utilizzo degli strumenti alla corretta pressione dell aria pu provocarne il funzionamento anomalo Non super...

Page 15: ...mergere i dadi arrugginiti in olio lubrificante fluido e rompere il blocco di ruggine prima di rimuovere il dado con la chiave pneumatica Se il dado non inizia a muoversi entro tre cinque secondi usar...

Page 16: ...la della valvola 4 la sfera della valvola 5 e il perno della valvola 6 dall impugnatura utilizzando una pinza a becco lungo Utilizzando un martello e un punzone rimuovere il perno a molla 10 e smontar...

Page 17: ...produits chimiques qui sont connus comme provoquant le cancer des anomalies cong nitales et d autres troubles reproductifs L inhalation des poussi res g n r es par le vissage peut causer des blessures...

Page 18: ...blessures Une pression pneumatique inad quate est susceptible d entra ner un fonctionnement irr gulier Ne pas d passer la pression pneumatique maximum de 90 psig 6 2 bar ou celle inscrite sur la plaq...

Page 19: ...oup de rouille et pour les fixations ressort qui absorbent beaucoup de la puissance d impact Si possible fixez ou calez l crou pour viter le retour lastique Faites tremper les crous rouill s dans de l...

Page 20: ...la soupape 5 et le poussoir de la soupape 6 de la poign e l aide d une pince bec long l aide d un marteau et d un poin on retirer la goupille du ressort 10 et retirer la g chette 12 Retirer la vis 15...

Page 21: ...aaien van schroeven Gebruik een goedgekeurd masker Schuren zagen slijpen boren en andere gereedschapsactiviteiten kunnen stofdeeltjes cre ren met chemische bestanddelen waarvan geweten is dat ze kanke...

Page 22: ...stand zijn tegen olie en geklasseerd zijn voor de werkdruk Slangen die barsten kunnen lichamelijk letsel veroorzaken Bij onjuiste luchtdruk kunnen pneumatische boren storingen geven Zorg dat de luchtd...

Page 23: ...k van U bouten lange dopschroeven dubbele schroefdraaddiepte moer ernstig geroeste bouten en veerringen omdat deze een groot gedeelte van de slagenergie absorberen Als het enigszins mogelijk is moet d...

Page 24: ...e cilinder 25 van de motorbehuizing Verwijder de slangadapter 1 van het gaspedaalhandvat en verwijder het gaspedaalveertje 4 de afsluiterbal 5 en de klep pen 6 van het gaspedaalhandvat met behulp van...

Page 25: ...ningsf rm gan Inandning av damm som skapas vid skruvdragning kan orsaka personskador Detta verktyg r inte isolerat mot kontakt med elektriska str mk llor Se till att inte anv nda verktyget n ra str mf...

Page 26: ...gsta till tna lufttryck p 90 psig 6 2 bar eller det som angivs p verktygets namnpl t eller i bruksanvisningen Anv nd luftregulator f r att bibeh lla r tt lufttryck Motordrivna verktyg som fungerar ob...

Page 27: ...enna sl ende mutterdragare r klassad f r bultstorlek 1 25 mm Detta m ste nedgraderas f r fj der U bultar dragbultar l nga sexkanth lskruvar djupa muttrar n r det r mycket rost samt vid fj drande f rba...

Page 28: ...rm tryck rotorn 23 och bakstycket 22 fr n motorhuset och tryck sedan cylindern 25 ut ur motorhuset Ta bort slangadaptern 1 fr n gasreglaget och ta bort gasreglagefj dern 4 ventilkulan 5 och ventiltapp...

Page 29: ...apping Screw 34 SP505624 O Ring 35 PT1800 11 Twin Cage 36 PT1800 13 Twin Hammer 2 IW1000MP 8H5 IW1000MP 8H8 PT1800 13 M Twin Hammer 2 IW1000MP 8H 37 SP506518 Twin Hammer Pin 2 38 PT1800L 12R Long Anvi...

Page 30: ...Normen oder Bezugnahme auf Spezifikationen anhand derer die Konformit t erkl rt wird Sicherheit ISO 11148 6 2010 Schwingungsemission ISO 28927 2 2009 Ger uschemission ISO 15744 2008 Der Bevollm chtigt...

Page 31: ...r f rences aux normes harmonis es utilis es ou r f renc es dans les sp cifications en vertu desquelles la conformit est d clar e S curit ISO 11148 6 2010 Vibration ISO 28927 5 2009 Bruit ISO 15744 200...

Page 32: ...erade standarder som anv nts eller h nvisningar till de specifikationer enligt vilka verensst mmelsen f rs kras Veiligheid ISO 11148 6 2010 Trilling ISO 28927 2 2009 Lawaai ISO 15744 2008 Den auktoris...

Page 33: ...33 ZCE831 Date 2019May7 D NOTES...

Page 34: ...arteggiatura segatura smerigliatura trapanatura con attrezzi elettrici e simili attivit pu contenere sostanze chimiche che causano cancro difetti congeniti o altri danni all apparato riproduttivo AVER...

Page 35: ...This pdf incorporates the following model numbers IW1000MP IW1000MP 8H IW1000MP 8H5 IW1000MP 8H8...

Reviews: