© 2003 - 2005 Sipura Technology, Inc
Proprietary (See Copyright Notice on Page 2)
103
4.13. Summary of SPA-3000 Configuration Parameters
This section summarizes the parameters that are specific to the SPA-3000 only. Other parameters
not included here are similarly defined in SPA; please consult the SPA administration guide for details
for those common parameters.
4.13.1. PSTN Line – Dial Plans
Parameter
Description
Default
Range
Dial Plan 1
The first of 8 dial plans in the dial plan pool to be
associated with a VoIP Caller or a PSTN Caller. Each
dial plan in the pool is referenced by a index 1 to 8
corresponding to Dial Plan 1 to 8. The dial plan
syntax is the same as that used for Line 1.
(xx.) Str512
Dial Plan 2–8
Same as above with ‘1’ replaced by ‘2’ – ‘8’
(xx.)
Str512
4.13.2. PSTN Line – VoIP-To-PSTN Gateway Setup
Parameter
Description
Default
Range
VoIP-To-PSTN
Gateway Enable
Enable/Disable VoIP-To-PSTN Gateway functionality
yes
Bool
VoIP Caller
Authentication
Method
Method to be used to authenticate a VoIP Caller to
access th PSTN gateway. Choose from {none, PIN,
HTTP Digest}
none Choice
VoIP PIN Max
Retry
Number of trials to allow VoIP caller to enter a PIN
number (used only if authentication method is set to
PIN)
3
1 – 10
One Stage Dialing
Enable one-stage dialing (applicable if authentication
method is none, or HTTP Digest, or caller is in the
Access List)
yes Bool
Line 1 VoIP Caller
DP
Index of the dial plan in the dial plan pool to be used
when the VoIP Caller is calling from Line 1 of the
same SPA-3000 unit during normal operation (ie, not
due to fallback to PSTN service when Line 1 VoIP
service is down). Choose from {none, 1, 2, 3, 4, 5, 6,
7, 8}
Note: Authentication is skipped for Line 1 VoIP caller
1 Choice
Default VoIP Caller
DP
Index of the dial plan in the dial plan pool to be used
when the VoIP Caller is not authenticated. Choose
from {none, 1, 2, 3, 4, 5, 6, 7, 8}
1 Choice
Line 1 Fallback DP
Index of the dial plan in the dial plan pool to be used
when the VoIP Caller is calling from Line 1 of the
same SPA-3000 unit due to fallback to PSTN service
when Line 1 VoIP service is down. Choose from
{none, 1, 2, 3, 4, 5, 6, 7, 8}
1 Choice
VoIP Caller ID
Pattern
A comma separated list of caller number templates
such that callers with numbers not matching any of
these templates will be rejected for PSTN gateway
service regardless of the setting of the authentication
method. The comparison is applied before access list
is applied. If this parameter is blank (not specified),
all callers will be considered for PSTN gateway
[blank] Str127