Last Caller Number
The number of the last caller
Mapped SIP Port
NAT Mapped SIP Port
Call 1/2 Status
State
State of the call: Idle, Dialing, Calling, Proceeding, Ringing, Answering,
Connected, Hold, Holding, Resuming, or Reorder
Tone
Tone playing for this call: Dial, 2
nd
Dial, Outside Dial, Ring Back, Ring, Busy,
Reorder, SIT1– 4, Call Waiting, Call Forward, Conference, Prompt,
Confirmation, or Message-Waiting
Encoder
Encoder in use: G711u, G711a, G726-16/24/32/40, G729a, or G729ab
Decoder
Decoder in use: G711u, G711a, G726-16/24/32/40, G729a, or G729ab
FAX
Indicate whether FAX pass-through mode has been initiated: Yes or No
Type
Indicate the call type: Inbound or Outbound
Remote Hold
Indicate whether the remote end has placed the call on hold: Yes or No
Call Back
Indicate whether the call is triggered by a call back request: Yes or No
Peer Name
Name of the peer
Peer Phone
Phone number of the peer
Duration
Duration of the call in hr/min/sec format
Packets Sent
Number of RTP packets sent
Packets Recv
Number of RTP packets received
Bytes Sent
Number of RTP bytes sent
Bytes Recv
Number of RTP bytes received
Decode Latency
Decoder latency in milliseconds
Jitter
Receiver jitter in milliseconds
Round Trip Delay
Network round trip delay (ms); available if the peer supports RTCP
Packets Lost
Total number of packets lost
Packet Error
Number of RTP packets received that are invalid
Mapped RTP Port
NAT mapped RTP port
Report Generation and Event Logging
The SPA reports a variety of status and error reports to assist service providers to diagnose problems and
evaluate the performance of their services. The information can be queried by an authorized agent (using
HTTP with digested authentication, for instance). The information may be organized as an XML page or
HTML page.
Error and Log Reporting
The SPA Error Status Code (ESC) is used to indicate the current operation status of the SPA unit. An
error state can be a relatively long transient state or a steady state. The state is also represented by a
special blinking pattern of the Status LED (next to the RJ-11 ports). The Error Status Code is a 4 digit
number. The first digit indicates the error class: 1xxx represents normal operation states while 2xxx –
9xxx represent error states that must be fixed for the unit to function properly. The status code values
can be read from the IVR option XXX or from the SPA web-page.
•
LED Blink Rate Definitions
•
ON – LED remains solid on
•
OFF – LED remains solid off
•
LONG (Long On) – 3.0s on, 1s off continuously
•
FAST – 0.125s on, 0.125s off continuously
•
SLOW – 0.5s on, 0.5s off continuously
•
VSLO (Very Slow) – 1.0s on, 1.0s off continuously
•