background image

 

Safety Instructions 

 

 

 

 

 

 

 

 

 

 

 

 

 

The  optical  devices  used  in  this  equipment  are  Hazard  Level  1M.  As  required  by  IEC60825-1,  the  installer  is  responsible  for  insuring  that  the  label 
depicted below is present in the restricted locations where this equipment is installed.  

 

 

 
 
 
This  assembly  contains  parts  sensitive  to  damage  by  electrostatic  discharge  (ESD).  Use  ESD  precautionary  procedures  when 
touching, removing, or inserting parts or assemblies.  

 
 

The DC power input connector serves as a service disconnect for this module. This module is intended for installation in locations 
that provide suitable access to the DC power input connector. 
 
 
 
 
The chassis into which this unit is installed must be housed in a properly rated NEMA enclosure. 
 
 
 
When this unit is operated in extremely elevated temperature conditions, it is possible for internal and external metal surfaces to 
become extremely hot. Care should be taken to insure this unit is installed in a restricted area where only properly trained 
service personnel have access to the unit. 

 

The safety information contained in this section, and on other pages of this manual, must be observed whenever this unit is operated, 
serviced, or repaired. Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of 
design, manufacture, and intended use of the unit. TKH Security Solutions USA assumes no liability for the customer’s failure to comply 
with any of these safety requirements. 

 

SA-1

 

 

LASER RADIATION  

DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (MAGNIFIERS) 

CLASS 1M LASER PRODUCT 

 

CAUTION:  

DISCONNECTED OPTICAL CONNECTORS MAY EMIT OPTICAL ENERGY.  

DO NOT VIEW BEAM WITH OPTICAL INSTRUMENTS (MAGNIFIERS) 

 

This product contains Class 1M lasers or LEDs.

   

• Class 1M laser product according to IEC60825-1:1993+A1+A2 
• 

CAUTION: Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure.          

• Precautions should be taken to prevent exposure to optical radiation when the unit is removed from its enclosure or when fiber is  
  disconnected from the unit. 
•Laser radiation may be present on a fiber connection to this unit even when the power has been removed from the unit. 
•This unit is intended for installation in locations where only trained service personnel have access to the fiber connections.

  

•The locations of all optical connections are listed in the Connection Locations and Function section of this manual. 
•Optical outputs and wavelengths are listed in the Specifications section of this manual.   

 

Hazard Level 1M 

The border shall be black and the                           
background shall be yellow 

 

   

 

Summary of Contents for 9961A-C

Page 1: ...Manual Model 9961A C Four Channel Option Module Host Multiplexer Demultiplexer For adding the capability to transport up to four Option Module channels via the HS Data Ports of a compatible Optelecom...

Page 2: ......

Page 3: ...eitungen 6 Consignes de S curit 7 Functional Description 8 9961A C Indicator Connector and Switch Location and Function 9 9961A C Configuration and Connection Guide 11 Operation of the 9961A C 13 Oper...

Page 4: ...caution warning or instruction noted in the manual is in violation of the standards of design manufacture and intended use of the unit TKH Security Solutions USA assumes no liability for the customer...

Page 5: ...ad Si no se cumple con alguna precauci n advertencia o instrucci n indicada en este manual se infringen los est ndares de dise o fabricaci n y el uso destinado a la unidad TKH Security Solutions USA n...

Page 6: ...tsmassnahmen Warnungen oder Anweisungen in diesem Handbuch nicht befolgt werden verst sst dies gegen die Konstruktions und Herstellungsstandards und erfolgt im gegensatz zum vorgesehenen Verwendungszw...

Page 7: ...n avertissement ou d une instruction figurant dans ce manuel est une violation des normes de conception fabrication et indication d usage de l appareil TKH Security Solutions USA n est pas responsable...

Page 8: ...C via a short Cat 5 cable The 9961A C clocks in the high speed data recovers frame sync separates the four data channels and routes them to the four Option Modules When a 9961A C is connected to a SIM...

Page 9: ...gnal transmitted by the local unit This LED will always be OFF when operated in SIMPLEX mode S1 7 or S1 88 is ON c PWR Green LED illuminates when when power is applied to the card d NOT SYNC Red LED i...

Page 10: ...ation and Operation Manual 4 7 OPTION MODULE INTERFACE LOCATIONS Up to four option modules are installed here 8 DIPSWITCH S1 These switches modify the operation of the LED indicators and the Tx CLOCK...

Page 11: ...ABLE 1 Switch Position Function 1 2 3 4 5 6 7 8 Duplex Operation Transceiver OFF OFF OFF OFF OFF OFF OFF HS Port Connection UP UP UP UP UP UP UP Simplex Operation Transmitter OFF OFF OFF OFF OFF ON OF...

Page 12: ...uits to allow for longer cable lengths The Option Module position 1 to 4 at one end of the link is electronically mated to the SAME Option Module position at the other end of the link 1 to 1 2 to 2 an...

Page 13: ...eive end will be illuminated Good data and or audio transmission will be apparent Operation of the 9961A C with Network Management System Software Operation of the 9961A C with the Network Management...

Page 14: ...Data and Audio Interface Specs See separate Option Module Installation and Operation Manual Audio Specs See separate Option Module Installation and Operation Manual Contact Closure Specs See separate...

Page 15: ...15...

Page 16: ...ouda The Netherlands Telephone 31 182 592 333 Fax 31 182 592 123 E mail sales nl tkhsecurity com TKH Security Solutions USA 12920 Cloverleaf Center Drive Germantown Maryland 20874 USA Telephone 1 301...