2. Indications and connectors 

 
Table  1  lists  the  front  panel  features  of  TETRA  43x0 
modules  (refer  to  figure  1).  Connector  pin  assignments 
are detailed in section 6. 
 

 

TETRA 43x0 TX 

 

o

 (SC/UPC connector)

 

Optical video/data out, optical 
data in 

o

 (BNC connector) 1-8

 

Composite video in 

TETRA 43x0 RX 

 

o

 (SC/UPC connector)

 

Optical video/data in, 
optical data out 

o

 (BNC connector) 1-8

 

Composite video out 

TETRA 43x0 TX and RX 

(4x)

 

Front panel screws 

AUDIO&DATA

 (modular front panel sockets): 

 

A1/CC1

  

audio 1, contact closure 1 

 

A2/CC2

 

audio 2, contact closure 2 

 

D1/D2

 

RS-485 (422)/ RS-232 

 

D3/D4

 

RS-485 (422)/ RS-232 

Status indicator LEDs 

 

 

SYNC                       

(red) 

 

(orange) 

 (green)

 

No sync from optical in, 
or no internal sync 
No sync @ remote opt. in  
All sync OK 

  DC 

(green)

 

DC power OK

 

 

NV                            

(red) 

TX: no video in 
RX: no video out 
Note:  They will always be OFF 
when the transmit input clamp is 
disabled. 

  *D1 

S422/485/Manchester                                          

(red/green)

 

If the data input is a steady logical 
“1”, or if there is data activity, the 
LED will be ON.  The LED color 
will follow the data, Red = 0/false, 
and Green = 1/True  

    D2

  RS232      ( red/green) 

  *D3

  R4224/85/Manchester                                          

(red/green)               

 

   D4

   RS232      ( red/green)

 

  10 

(on Ethernet Port,  

Amber)

 

ON with LINK at 10 Mbps, Blinks 
with Activity 

  100 (

 on Ethernet Port, 

Green)

 

ON with LINK at 100 Mbps, Blinks 
with Activity 

 

 
 
 
 
 
3. Configuration 

 
To access the internal set-up switches for the audio, data, 
and  Ethernet  circuits,  remove  the  four  screws  on  the 
front panel as indicated in figure 3, below, and slide out 
the circuit card assemblies. 
 

Contact  Closures

   

There  is  no  set-up  required  for 

Contact  Closure  operation.  Refer  to  fig.  4  for  hook-up. 
At  the input, connect the input contacts between CC IN 
and GND. When this connection is made at the input, the 
CC  OUT  A  and  CC  OUT  B  outputs  at  the  far  end  are 
connected  together.  If  SYNC  is  lost,  the  contacts  open.

  

 

Figure 3.  Access to internal configuration switches and 

jumpers 

 
Data  interface  selection

:  The  four  position  D1/D3  SEL 

dip  switch  (S4)  settings  determine  whether  the  D1  and 
D3 data ports operate in RS-422, RS-485 4W, RS-485 
2W, or Manchester (Bi-phase) mode, per table 2.  
In  addition,  properly  setting  the  Four  position  LINE 
BIAS,  CONFIGURATION,  AND  TERMINATION  dip 
switches is essential  for proper operation.  See  figure 2, 
table  3,  and  the 

R-S422,  R-S485,  and  Manchester  Line 

Bias, Configuration, and Termination

 section. 

 
 

Figure 2. Location of configuration jumpers on the 

Data/Audio/Ethernet Circuit Card.  To access, see 

“Configuration”, and figure 3.

 

 

Table 1. TETRA 43x0 front panel features 
* If the D1 or D3 LED indicates steady Green when the 
input is connected but no signal is being transmitted, either 
the leads are reversed or, if not, the input  bias (BR) should 
be enabled. 

 

Summary of Contents for TETRA 4310

Page 1: ...l individually be set to transparent mode i e video clamping off and the video channel operation mode and several switching functions are accessible through software using the SmartNet management syst...

Page 2: ...t 100 Mbps Blinks with Activity 3 Configuration To access the internal set up switches for the audio data and Ethernet circuits remove the four screws on the front panel as indicated in figure 3 below...

Page 3: ...d towards V and the B input is biased towards V This bias ensures that the input line receiver interprets the state of the differential bus as a logical zero while all the drivers attached to the diff...

Page 4: ...es and connect suitable video and optical fiber equipment using appropriate cabling CLEAN THE OPTICAL FIBER CONNECTORS PRIOR TO INSERTION INTO THE OPTICAL PORT For long electrical links twisted pair w...

Page 5: ...0 to 20K Hz Sampling resolution 16 bit In output level 0 nom 9 max dBV SNR 77 dB Total harmonic distortion 0 25 at nominal level In output impedance 50 k or 600 in 50 out bal Data Number of channels 4...

Page 6: ...Before opening the equipment disconnect it from all power sources The equipment must be powered by a SELV power supply When this unit is operated in extremely elevated temperature conditions it is po...

Page 7: ...o fail EMC requirements Non video signal lines must use appropriate shielded CAT5 cabling S FTP or at least an equivalent If system components such as cabling e g coaxial cable data audio cc wiring an...

Reviews: