EMC 

The  equipment  has  been  tested  and  found  to  meet  the  CE-
regulations  relating  to  EMC,  and  complies  with  the  limits  for  a 
Class B device, pursuant to Part 15 of the FCC rules. 

These limits 

are  designed  to  provide  reasonable  protection  against  interference  to 
radio  communications  in  any  installation.  The  equipment  generates, 
uses and can radiate radio frequency energy; improper use or special 
circumstances  may  cause  interference  to  other  equipment  or  a 
performance decrease due to interference radiated by other equipment. 
In  such  cases,  the  user  will  have  to  take  appropriate  measures  to 
reduce such interactions between this and other equipment. 

Any interruption of the shielding inside or outside the equipment could 
cause the equipment to be more prone to fail EMC requirements. 

Non-video  signal  lines  must  use  appropriate  shielded  CAT5  cabling 
(S-FTP), or at least an equivalent. 
If  system  components,  such  as  cabling  (e.g.  coaxial  cable, 
data/audio/cc wiring) and/or the units, are used outdoors, ensure that 

all 

electrically  connected  components  are  carefully  earthed  and 

protected against surges (high voltage transients caused by switching 
or lightning). 

 

ESD 

Electrostatic  discharge  (ESD)  can  damage  or  destroy  electronic 
components.  Proper  precautions  should  be  taken  against  ESD 
when opening the equipment.

 

 

*)

  SELV:  conforming  to  IEC  60950-1,  <60V

DC

  output,  output  voltage 

galvanically  isolated  from  mains.  All  power  supplies  or  power  supply 
cabinets available from Siqura comply with these SELV requirements. 
 

 

9. Product disposal 

 

Recycling 

The unit contains valuable materials which qualify for 
recycling.  In  the  interest  of  protecting  the  natural 
environment, properly recycling the unit  at the end of 
its service life is imperative. 

 
 

 
 

 

 
 
 

 
 
 
 
 

Summary of Contents for TETRA 4310

Page 1: ...l individually be set to transparent mode i e video clamping off and the video channel operation mode and several switching functions are accessible through software using the SmartNet management syst...

Page 2: ...t 100 Mbps Blinks with Activity 3 Configuration To access the internal set up switches for the audio data and Ethernet circuits remove the four screws on the front panel as indicated in figure 3 below...

Page 3: ...d towards V and the B input is biased towards V This bias ensures that the input line receiver interprets the state of the differential bus as a logical zero while all the drivers attached to the diff...

Page 4: ...es and connect suitable video and optical fiber equipment using appropriate cabling CLEAN THE OPTICAL FIBER CONNECTORS PRIOR TO INSERTION INTO THE OPTICAL PORT For long electrical links twisted pair w...

Page 5: ...0 to 20K Hz Sampling resolution 16 bit In output level 0 nom 9 max dBV SNR 77 dB Total harmonic distortion 0 25 at nominal level In output impedance 50 k or 600 in 50 out bal Data Number of channels 4...

Page 6: ...Before opening the equipment disconnect it from all power sources The equipment must be powered by a SELV power supply When this unit is operated in extremely elevated temperature conditions it is po...

Page 7: ...o fail EMC requirements Non video signal lines must use appropriate shielded CAT5 cabling S FTP or at least an equivalent If system components such as cabling e g coaxial cable data audio cc wiring an...

Reviews: