Italy 100 cutter
Use and Maintenance Manual Ver. 1.1
9
2.2
G
ENERAL NOTES
•
The machine is intended for industrial use in normal environmental conditions as
defined in point 4.4 of EN 60204-1. These conditions refer to machine use.
•
The machine may only be used by specifically trained staff and who have read the
contents of this manual.
•
The machine is manually operated.
2.3
A
IRBORNE NOISE EMISSION
The sound pressure level was measured in the normal operator working position, i.e.
20cm from the short side of the machine where the tile positioning squares are located.
The value indicated in the table below refers to the machine operating with a continuous
crown disc.
Measurement
Sound pressure (dB)
Sound pressure level
90.5 dB (referring to
20
µ
µPa)
Sound power level
97 dB (referring to 1pW)
The measurements were made in accordance with ISO 11201 and ISO 3744.
The sound pressure level generated by the machine is such that anti-noise
protection must be used (headset or ear plugs).
2.4
T
ECHNICAL DATA
The table below lists the technical data of the machine.
Parameter
Value
Electrical power supply
SEE THE MOTOR IDENTIFICATION PLATE
Absorption
SEE THE MOTOR IDENTIFICATION PLATE
Motor rpm
SEE THE MOTOR IDENTIFICATION PLATE
Motor condenser capacity
SEE THE MOTOR IDENTIFICATION PLATE
Degree of protection
SEE THE MOTOR IDENTIFICATION PLATE
Insulation class
F
Maximum cutting length
100 cm
Maximum length for 45° angle cut
100 cm
Maximum tile sides for 45° cut
70cm x 70cm
Maximum cutting height
42 mm
Diamond disc type
200mm Ø continuous crown
Weight 55
kg
Dimensions
154 x 57 x 106 cm (LxDxH)
The operating temperature must be between 0 and 45°C