background image

4

This installation should only be performed by a qualified tradesperson. Where possible, use a trained Sirius recommended 
installer (see Siriusbrand.com). Sirius will not be held responsible for issues that occur due to installation of product by an 
unqualified tradesperson.

•  Motor must be accessible for servicing purposes. If not, servicing may be refused unless access can be provided. 

Prior to install please check minimum & maximum installation details on the Sirius website, FAQ under support tab. 
Service is offered during normal business hours only, also appliances to have a clear access in a serviceable area.

•  The ducting of the rangehood must not be connected to ducting which is used for exhausting other fumes from 

appliances, such as central heating, boilers etc.

•  For the external exhausting of the fumes, comply with the Australian building standards.
•  Ventilate the room suitably according to the Australian building standards when the appliance is working together with 

gas or oil appliances.

•  The SEM motor is powered by the rangehood. Standard 10AMP GPO at the point of rangehood required.
•  Before connecting the rangehood to the mains supply, make sure that the voltage indicated in the rating plate 

corresponds to the mains voltage in the home.

•  Before carrying out any sort of maintenance or cleaning operation, make sure that the appliance is disconnected from 

the electrical mains.

 

IMPORTANT INFORMATION BEFORE INSTALLATION IN YOUR SIRIUS RANGEHOOD

•  FLASHING NOT INCLUDED

•  Sirius has metal and tiled roof flashing available in various sizes from your retailer,  

or visit www.siriusbrand.com

•  Rangehood and SEM5 XS316 must be a minimum of 2 metres between rangehood and motor for noise reduction 

reasons.

•  Only use ducting that falls within the necessary minimum and maximum length requirements as specified in the 

installation guide.

•  Try and minimise bends to the ducting for optimum performance.
•  Use only suitable ducting as specified by Sirius. Under no circumstances is flexible ducting to be used as it creates 

unwanted noise, vibration and can place the motor under unnecessary stress resulting in premature failure of the SEM 
motor. 

•  Under no circumstances is the duct diameter is the duct diameter to be reduced. A constant minimum diameter of 

150mm for the SEM 5 must be maintained at all times. 

•  Read the mounting and operating instructions of the rangehood carefully.
•  The manufacturer cannot be held responsible for a decrease of the airflow or for an increase of noise level caused by 

non-compliance with the instructions above.

BEFORE YOU INSTALL

WARNING

1. Remove the four screws holding the front of the housing in place to 
expose the connections.

2. Following the wiring chart on the front of the housing, connect each wire 
to the matching colour, making sure that this is done correctly before running 
power to the unit.

3. Replace the cover and fix the four screws back into place.

MOTOR WIRING CONNECTION

Summary of Contents for SEM51

Page 1: ...1 SEM51 User Installation Manual when Sirius ducting is used Full replacement warranty on parts and labour Year Warranty www siriusbrand com ...

Page 2: ...2 ...

Page 3: ...NSTALL MOTOR WIRING CONNECTION 4 BEFORE YOU INSTALL DUCTING INFORMATION 5 INSTALLING THE SEM51 MOTOR 6 OPTIONAL MESH FILTER 8 BRACKET AND INTERNAL PIPE DIMENSIONS 9 SEM51 MOTOR WIRING DIAGRAM 10 WARRANTY INFORMATION 11 TABLE OF CONTENTS ...

Page 4: ...ected from the electrical mains IMPORTANT INFORMATION BEFORE INSTALLATION IN YOUR SIRIUS RANGEHOOD FLASHING NOT INCLUDED Sirius has metal and tiled roof flashing available in various sizes from your retailer or visit www siriusbrand com Rangehood and SEM5 XS316 must be a minimum of 2 metres between rangehood and motor for noise reduction reasons Only use ducting that falls within the necessary min...

Page 5: ... service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airflow Sirius Semi rigid or solid ducting can be used in lieu There is a range available to suit any application Ducting available at www siriusbrand com 6 Year Warranty when Sirius Ducting is used Full replacement warranty on parts an...

Page 6: ...iusbrand com Metal roof flashing code MRF G178 Tiled Roof Flashing code TRF G075 4 Fix the 200mm pipe to the internal bracket with the 8 x supplied 9 5mm screws Please note that the 200mm pipe has no pre drilled holes and will need to be drilled at the desired height by the installer A minimum of 100mm exposed section of 200mm pipe is required to accomodate the flashing Fig 3 INSTALLATION Fig 3 8 ...

Page 7: ...de Fig 4 9 Run the ductwork from the motor location back to the location of the rangehood Connect the ductwork to the plastic outlet collar on the rangehood and secure in place Please note do not use screws to fix the ductwork to the rangehood as it will prevent the non return valves from opening during operation 10 Plug the rangehood into a 10 amp GPO located within 1 Metre of the rangehood Press...

Page 8: ...AL40 MESH OPTIONAL Part number SPS 75105000598 Remove the 4 screws holding the existing ventillation cover in place and take off Fit the BAL40 mesh into place and replace the 4 screws Refer to Fig 6 Fig 6 ...

Page 9: ...9 BRACKET AND INTERNAL PIPE DIMENSIONS 600mm 515mm 200mm diameter 254mm Top view Side view Flue ceiling brace 254mm 71mm ...

Page 10: ...10 SEM51 MOTOR WIRING DIAGRAM ...

Page 11: ... Sirius s Total Peace of Mind Protection Plan Australian New Zealand 3 6 Year Protection Plan This guarantees your appliance for a full 3 years parts and labour 10 years for the off board motors covering manufacturing defects only from the date of purchase subject to the Terms and Conditions overleaf 3 Year warranty is extended to a 6 year period only when Sirius ducting is installed Year Warranty...

Page 12: ...ranty will not apply where a The fault is caused by accident misuse an infestation of insect and or vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been a failure to comply with the manufacturer s operating and installation instructions c Service modification or repair has been carried out by anybody other than an approved Arisit Service Technician d The app...

Reviews: