background image

Sirius Technologies ST301U/ST302U 

USB Data Logger 

Operating Manual V1.0 

 

418-B Cloverleaf Dr. Baldwin Park, CA 91706 

TEL:(626)934-0100 



FAX:(626)934-0161 



E-Mail: INFO@SIRIUSTEC.COM 

 

 

 

ST301U/ST302U 

USB Data Logger 

 
 
 

 

Table of Content 

 
 

1. Specifications

………………………………………………..….………

Page 2

 

 

2. Data Logger Content

………………………………………...……….. 

Page 3

 

 

3. Installation Requirement

…………………………………….………..

Page 3 

 

4. Hardware Setup

……………………………………………….………

Page4-9 

 
5. Software Installation

……………………………………….……..

Page 10-15 

 
6. Data Logger Setup

…..…………………..………………………..

Page 16-22 

 
7. Data Logger Data Download

……………...…………….……....

Page 23-29 

 
8. Using other software functions

…………………………………

Page 30-34 

  File 

  Logger 

  View 

  Test COM port 

 

9. 

Warranty

…………………………………………………………..…

Page 35

 

 
 
 
 

Summary of Contents for ST301U

Page 1: ...TEC COM 1 ST301U ST302U USB Data Logger Table of Content 1 Specifications Page 2 2 Data Logger Content Page 3 3 Installation Requirement Page 3 4 Hardware Setup Page4 9 5 Software Installation Page 10 15 6 Data Logger Setup Page 16 22 7 Data Logger Data Download Page 23 29 8 Using other software functions Page 30 34 File Logger View Test COM port 9 Warranty Page 35 ...

Page 2: ... Specifications Specifications Model ST301U ST302U Type Temperature Temperature Humidity Channels 1 2 Range 20 C to 70 C 40 C to 85 C Temp Accuracy 0 7 C at 21 C 0 7 C 25 C Humidity Range 0 100 RH Humidity Accuracy 2 5 Rh 20 80 Rh Resolution 12 Bits 12 Bits Memory 64K 128K Interface USB USB of reading 30 000 60 000 30K Pairs Sensor Internal Internal Sensor Thermistor Temp Hum ...

Page 3: ...TEC COM 3 2 Data Logger Content 1 Data Logger Unit 2 USB Cable 3 Installation Disk 3 Installation Requirements Minimum system requirements for the software Pentium III 500 MHz processor or equivalent with 128 Megabytes of RAM Optimal Performance Pentium 4 2 8 gigahertz processor or equivalent with 256 Megs or ram Operating System Requirements Windows 2000 Windows XP ...

Page 4: ...ger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 4 4 Hardware Setup 4 1 Connect small end of cable to the data logger 4 2 Connect large end of the cable to PC s USB port ...

Page 5: ...r Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 5 4 3 Found New Hardware Window will identify ST300 s USB connection driver as CP2103 USB to UART Bridge Controller Fig 4 3 ...

Page 6: ...91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 6 4 4 Ready to Use Window will install the USB driver automatically It only needs to install once The message Found New Hardware Your new hardware is installed and ready to use confirms the USB driver is successfully installed It s ready to use ...

Page 7: ... FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 7 4 5 Driver Verification Click on Start Click on Control Panel Click on System on click Hardware Click on Device Manager Click on Port COM and LPT Identify CP210X USB to UART Bridge Controller If it s there the driver has been successfully installed Fig 4 5 1 Correct USB Driver property ...

Page 8: ...chnologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 8 4 5 2 Correct USB Driver property Fig 4 5 2 ...

Page 9: ...hnologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 9 4 5 3 Correct Driver Version 5 1 0 0 Fig 4 5 3 ...

Page 10: ...er Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 10 5 Software Installation 5 1 Insert the CD into the disk drive Fig 5 1 5 2 Click on Setup to start installation Fig 5 2 ...

Page 11: ...2U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 11 5 3 Follow the Installation Shield Wizard s installation instruction Click Next Fig 5 3 ...

Page 12: ... USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 12 5 4 Select destination folder and click Next to continue Fig 5 4 5 5 Click Next to continue ...

Page 13: ...ius Technologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 13 Fig 5 5 5 6 Installing program ...

Page 14: ... ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 14 Fig 5 6 5 7 Installation completed Click Finish to complete the setup program ...

Page 15: ...irius Technologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 15 Fig 5 7 6 Data Logger Setup ...

Page 16: ... Mail INFO SIRIUSTEC COM 16 6 1 The ST300U series data logger requires the user to setup the data logger from the PC interface program From Window s start menu Click on All programs Click on Sirius Data logger Click on ST300 DATA LOGGER to start the PC program Fig 6 1 ST301 Data logger software main menu 6 2 Click on the icon to start the Setup menu ...

Page 17: ...ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 17 Fig 6 2 1 or Fig 6 2 2 Click on Logger click on Setup to enter the setup screen ...

Page 18: ... Technologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 18 6 3 Setup menu Figure 6 3 Setup Menu ...

Page 19: ...626 934 0161 E Mail INFO SIRIUSTEC COM 19 6 3 1 Data logger information and real time display Fig 6 3 1 1 Product Name Model 2 Date Current Date and Time 3 Maximum Record Number Maximum of records can be stored in a data logger 4 Temperature F Real Time Temperature F 5 Temperature C Real Time Temperature C 6 Humidity Real Time Humidity ...

Page 20: ...Select sampling Interval 2sec 3sec 4sec 5sec 6sec 7sec 8sec 9sec 10 sec 15sec 30sec 45 sec 1min 5min 10min 20min 30min 1hr 3hr 8hr 9 Start Time Data logger start record time No user input 10 End Time Data logger end record time No user Input 11 Delay Start Set Delay start time 12 Data logger PC connection status Connection status Green connected Red not connected 13 Battery Status Real Time batter...

Page 21: ...CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 21 6 3 3 Real Time Graph Display Fig 6 3 3 15 Temperature Real Time Real Time temperature display 16 Humidity Real Time Real Time Humidity display Display real time temperature and humidity value from the data logger 6 4 Using Delay Start ...

Page 22: ... FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 22 Check Delay Start box The Start Date Time window will light up Select the Start Date to start the data logger End Time will be computed automatically according to the start date time and interval values Click Save Setting to save the settings to the data logger Data logging will start ...

Page 23: ...l V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 23 7 DATA Download 7 1 Click on the icon to start the Download menu Fig 7 1 or Click on Logger Click on Download Records to start the Download menu Fig 7 1 1 ...

Page 24: ...USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 24 7 2 The software will try to establish the connection between PC and the data logger Fig 7 2 ...

Page 25: ...rius Technologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 25 7 2 Data logger Found Fig 7 3 ...

Page 26: ...ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 26 7 4 Save the data in adc file format Fig 7 4 Enter adc file name ...

Page 27: ...ual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 27 7 5 Downloading Record Fig 7 5 Once the connection is established the software will automatically download all the records in the data logger to the PC ...

Page 28: ...a Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 28 7 6 Download success Fig 7 6 Data is downloaded to the PC It s ready for viewing Click OK to view the data ...

Page 29: ... Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 29 7 7 Viewing Data Fig 7 7 The right column is for data display The left column is for data graphic display Move the cursor up or down to scroll through the data The black data line corresponds to the high lighted data entry ...

Page 30: ...E Mail INFO SIRIUSTEC COM 30 8 Using Other Software Functions 8 1 FILE 8 1 1 Open Click on Open to open the file in adc format 8 1 2 Export Data to Excel File Save download data in Excel format 8 1 3 Print Data Print data in data format 8 1 4 Print Chart Print data in Graphic format 8 1 5 Exit Click on Exit the ST300 data logger program 8 2 Logger ...

Page 31: ...anual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 31 8 2 1 Setup Click Setup to enter Setup screen 8 2 2 Download Records Click Download to Download screen 8 2 3 Test COM Port Test available COM port ...

Page 32: ...ologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 32 8 2 3 Test COM Port COM Port available Fig 8 2 3 ...

Page 33: ...Technologies ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 33 8 2 4 COM port not available Fig 8 2 4 ...

Page 34: ...s ST301U ST302U USB Data Logger Operating Manual V1 0 418 B Cloverleaf Dr Baldwin Park CA 91706 TEL 626 934 0100 FAX 626 934 0161 E Mail INFO SIRIUSTEC COM 34 8 3 View Click on Temp F or Temp C to change temperature unit ...

Page 35: ...n material or workmanship This warranty does not apply to damage resulting from accident alteration abuse loss of parts or repair by other than Sirius Technologies Inc The equipment will be repaired or replaced at our option without charge to the owner for parts or labor incurred in such repair This warranty shall not apply unless the equipment is returned for our examination with all transportati...

Reviews: