SIRS NAVIGATION LTD
COMPONENT MAINTENANCE MANUAL
The compass must be installed with two ‘non-magnetic’ screws, with a head
diameter of dimension 6.5mm to 6.9mm.
CAUTION:
THE SCREWS THAT ATTACH THE COMPASS MUST NOT
BE OVER-TIGHTENED.
NOTE: Refer to the installation drawing for detailed information.The compass
does not need electrical power to operate, other than for illumination. The
compass will operate after installation and ‘magnetic correction’.
Magnetic correction is required to correct for magnetic errors caused by
the aircraft, local components or instruments. A correction procedure for
the compass is specified in page Block 11001 Special Procedures.
E. Leading Particulars
The leading particulars for each compass are shown in table 1 below
Code
Siz
e
Weight
Voltage (dc)
Ambient
Operating
Temperture.
Lamp
Resistor
Body Colour
Card Legend
Colour
KCA0101W
Height: 51.0mm (2.00in)
W
idth: 57.5mm (2.26in)
Depth: 49.0mm (1.93in)
0.09KG
(3.5 oz)
None None
White
KCA0104W
330
Ω
White
KCA0104FY
330
Ω
Fluorescent Yellow
KCA0105W
330
Ω
B
lack
White
KCA0106W
330
Ω
Grey White
KCA0112W
820
Ω
White
KCA0113W
390
Ω
White
KCA0113FY
390
Ω
Fluorescent Yellow
KCA0114W
28v
47
Ω
White
WL1001KCA1
Height: 57.5mm (2.26in)
W
idth: 57.5mm (2.26in)
Depth: 51.5mm (2.03in)
0.113KG
(4 oz)
5v
-40
°
C to +
8
0
°
C
None
B
lack
White
Standby Compass - Leading Particulars
Table 1
PAGE 3
APR 10/03
34-25-21
The document reference is online, please check the correspondence between the online documentation and the printed version.