10
11
4
CBD6S Control Box(4)
*** For technical support please call 1.800.374.7438 #2007, servicetech@sisergo.com ***
Page: 5 of 5
Elle Series
4-Leg Electric
Optional Battery Pack Installation
14. Place battery pack (10) in cable tray.
NOTE:
For frame models that do not utilize a cable tray
mount battery pack (10) to underside of worksurface using
two 10mm screws.
15. Connect a DC cable (11) to the battery pack (10) and
the opposite end to the port in the control box(4) labeled
"DC".
16. Charging: To charge the battery pack(10), connect the
control box(4) to the 120v power cord (6) and the other
end to a 120V outlet and wait until all LED light bars have
turned off, indicating that the pack is fully charged
(Approximately 5 hours).
17. Troubleshooting: If the battery pack (10) stops working,
disconnect the DC cable(11). Then press the button on the
pack for a minimum of 10 seconds. After doing this, charge
the battery pack(10) using step 17, and reconnect.
Tools required: Drill driver, PHILLIPS bit PH2. Hex key 4mm.
BA001 Battery Box(10)
DC Cable
with 2-Pole
Minift Plug(11)
Appropriate Mains Cable