CONNECTION DIAGRAM

ENDA ETM742 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The 
shielding must be grounded on the instrument side. During an installation, all of the cables that are connected to the device must 
be free of energy. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the 
operation temperature is not exceeded. All input and output lines that are not connected to the supply network must be laid out as 
shielded and twisted cables. These cables should not be close to the power cables or components. The installation and electrical 
connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations. 

1) Mains supply cords shall meet the requirements of  IEC 60227  
    or IEC 60245. 
2) In accordance with the safety regulations, the power supply 
    switch shall bring the identification of the relevant instrument 
    and it should be easily accessible by the operator.

Note 

Holding screw 0.4-0.5Nm

Equipment is protected throughout
by DOUBLE INSULATION.

12

11

184-253V AC
   veya 
10-30V DC/
 8-24V AC
50/60Hz 7VA

230V AC

 / LV

 Supply

Switch

Cable size: 1,5mm²

Fuse

F 100 mA

 250V AC

Neutral

Line

SUPPLY :

NOTE :

Fuse should
be connected.

TERMS

(1) Time value during run mode.
      Parameter value or mnemonic parameter code  during programming mode.
      
     

(3) Output LED.

(2) Set value or time unit during run mode.
      Parameter value, unit or mnemonic parameter code  during programming mode.

(5) Increment key during run and programming modes.
      Parameter selection key during programming mode.
(6) Parameter selection and reset key during programing mode.
     Decrement key during run and programming mode.

(7) Used for selecting 

option

s or digits to be changed. 

(8) Used for selecting run or programming modes or for adjusting the parameter.     

  One red  LED

      Micro switch

  ( 2 ) SV display

         Character height

  ( 3 ) Output LED

  ( 4 ),( 5 ),( 6 ),( 7 ) Keypad

  ( 1 ) PV  display

(4) Run LED.

  PV display (1) :    14.2mm       

  SV display (2) :    10.2mm       

      4 digits, 7 segment red LED 

      4 digits, 7 segment yellow LED

      DIGITAL TIMER

ENDA

ETM 742

OUT

PV

SV

RESET

PRESET

SET

RUN

Panel 

cut-out

De

pth

97mm

75mm

8

4

m

m

 68     mm

+0.7

 6

8

  

  

 m

m

+0

.7

2

Note  1) While panel mounting, additional distance required 
              for connection cables should be considered.
          2) Panel thickness should be maximum 10mm.
          3) If there is no 90mm free space at back side of the device,
              it would be difficult to remove it from the panel.

 

 -  

Push the flush-mounting 

     clamp in direction 

1

 as    

     

shown in the figure left.

 

 -  

Then, pull out the clamp in  

     

direction 

2.

 

For removing mounting clamps:

Connection

 

c

ables

Rubber packing

Flush mounting

 

clamp

Panel

1

2

1

DIMENSIONS

7

2

m

m

7

8

m

m

      DIGITAL TIMER

ENDA

ETM 742

OUT

 

RUN

PV

SV

RESET

PRESET

SET

ENDA

INDUSTRIAL ELECTRONICS

E

TM

742-230

DIGITAL TIMER

230

V AC

  

 50/60Hz 7VA

 

OUT1

 AC 250V 2A
 RESISTIVE
 LOAD

11

12

13

14

15

SN: XXXXXXXXX

8

7

  

START

     GATE

6

5

 

 RESET

   

 S.S. OUT

9

  

GND

10 

+12

V

 50mA

  

NC

NO

C

ENDA

INDUSTRIAL ELECTRONICS

E

TM

742-

SM

 

DIGITAL TIMER

SN: XXXXXXXXX

8

7

  

START

     GATE

6

5

 

 RESET

   

 S.S. OUT

9

  

GND

10 

+12

V

 50mA

  

 

OUT1

 AC 250V 2A
 RESISTIVE
 LOAD

11

12

13

14

15

NC

NO

C

8 680407 700134

8 680407 700158

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

ENDA

TM

Summary of Contents for ENDA ETM742

Page 1: ...TECHNICAL SPECIFICATIONS 80 up to 31 decreasing linearly 50 at 40 C C According to EN 60529 Front panel IP65 Rear panel IP20 Do not use the device in locations subject to corrosive and flammable gases Supply 230V AC 10 20 50 60Hz 10 30V DC 8 24V AC SMPS Power consumption Max 7VA 2 5mm screw terminal connections Wiring Date retention EMC Safety requirements EN 61326 1 1997 A1 1998 A2 2001 Performan...

Page 2: ...ing run and programming modes Parameter selection key during programming mode 6 Parameter selection and reset key during programing mode Decrement key during run and programming mode 7 Used for selecting options or digits to be changed 8 Used for selecting run or programming modes or for adjusting the parameter One red LED Micro switch 2 SV display Character height 3 Output LED 4 5 6 7 Keypad 1 PV...

Page 3: ...tion Prog yES Prog yES Prog yES No menu is seen No menu is seen No menu is seen Timer can not be reset Both RESET input and the key can be used for resetting See NOT 2 for modification See NOT 2 for modification See NOT 2 for modification Menu is seen but can not be programmed Menu is seen and programming is possible Menu is seen but can not be programmed Menu is seen and programming is possible M...

Page 4: ...ART becomes passive timer stops and initial conditions are returned NOTE if Gate input becomes active timer enters into wait mode Timer waits at that condition until gate input becomes passive Without memory With memory TON Relay On time TOFF Relay Off time t Partial time of TON or TOFF Indefinite time While the device is energized If START input is active first TON and then TOFF times are passed ...

Page 5: ... Fuse F 100 mA 250V AC RESET START GATE NOTE FOR PNP SENSOR TYPE ACTIVE LEVEL IS AUXILIARY POWER SUPPLY VOLTAGE NPN PROXIMITY SWITCH GND OUT active level GND 12V OUT active level is sensor supply voltage GND 230V AC LV Supply Switch Cable size 1 5mm Fuse F 100 mA 250V AC RESET START GATE 230V AC LV Supply Switch Cable size 1 5mm Fuse F 100 mA 250V AC SİSEL MÜHENDİSLİK ELEKTRONİK SAN VE TİC A Ş Şer...

Reviews: