Run mode

Depending on the value of the            parameter 

bottom display shows time unit or one of the 

set values 

(

)

.

        

        

Ton 

or 

 

Toff

OutP.

oPtý.

dýsP.

oPtý.

SECU.

oPtý.

Sensor type can be selected as  

nPn

 or

 

PnP

  This selection affects all 3 inputs.  

See NOTE 2 for modification.

OutP.

typE

mEm.

Set.

There are 9 different output types.

O

utput types are at the next page.

See NOTE 2 for modification.

Device can be operated with memory or
without memory modes for 9 output types.  
See NOTE 2 for modification.

Bot.

DÝSP.

Bottom display value can be selected. 
If 

BASE

 

is selected, one of the time units 

(

Sec. Min

 

Hour

is displayed. 

If 

Set

is selected, 

Ton

 

or 

Toff

 value is 

displayed. 
See NOTE 2 for modification.

WARNING:  

As the selected time interval changes 

by           parameter, time unit also changes.

 

                   

.

 or

 

ýnP.o.

SECU.

Out.o.

SECU.

dýs.o.

SECU.

SECU.

codE

Time.

r.SEt

def.

SEt

Counting direction can be selected as  

Up

 or 

dn.

 

See NOTE 2 for modification.

Minimum On and Off times for the pulses of 
the external inputs (RESET, START and GATE) 
can be selected. This selection affects all 3 inputs.
See NOTE 2 for modification.

There are 9 different time intervals. 
They are 
0-99.99s, 0-999.9s, 0-9999s
0-99.99min, 0-999.9min, 0-9999min
0-99.99h, 0-999.9h and  0-9999h.

Warning

: Changing this parameter 

affects the values of 

Ton

 

ve 

Toff

.

See NOTE 2 for modification.

   29.8

  200.0

Ton

 

or 

Toff

 

See  NOTE 1 for adjusting the set value.

 

 

Bot.

DiSP

.

 Set

Time

bAsE

  

Time

bAsE

Sens.

TYPE

týmE.

Dir.

puls

time

ýnPt.

oPtý.

  

Bot.

DiSP.

  29.8

  Sec.

 Toff

 200.0

PRESET

SET

PRG

 Ton

100.0

BASE

ETM742-EN-08-220103

SET

 if            key is pressed while holding           key, the

 programming mode is enabled.

Access code for entering security option menu.
This parameter should be 

1111

.

See NOTE 2 for modification.

Prog.
yES

Prog.
yES

Prog.
yES

= No menu is seen.

= No menu is seen.

= No menu is seen.

= Timer can not be reset.

= Both RESET input and the         key can
   be used for resetting.

See NOT 2. for modification.

See NOT 2. for modification.

See NOT 2. for modification.

= Menu is seen but can not be programmed.
 
= Menu is seen and programming is possible.

= Menu is seen but can not be programmed.
 
= Menu is seen and programming is possible.

= Menu is seen but can not be programmed.
 
= Menu is seen and programming is possible.

nonE

nonE

nonE

no

Prog.
 no

Prog.
 no

Prog.
 no

 

both

= Timer can be reset by         key.

= Timer can be reset by the RESET input.

See NOT 2. for modification.

PAnE.
r.SEt

r.SEt
inP.t.

While leaving the programming mode,

no

 

  

= All the modifications are saved.

Yes

 

=Default values are set to parameters.

See NOT 2. for modification.

PARAMETER  MODIFICATION DIAGRAM

NOTE 1

NOTE 2

While holding         key in the run mode, 

 

toff

 

parameters appear.  By using                keys ,

the value can be adjusted.

       

          

ton

  and 

   

            

While holding        key, parameters of the menu can be changed by using                keys.

 3/5

PRESET

PRESET

PRESET

PRESET

PRESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

RESET

SET

PRESET

0.010
 sec.

0.020
 sec.

0.050
 sec.

0.100
 sec.

0.005
 sec.

tImE     
bA5E

    

Puls
timE

99.99
 Sec.

999.9
 Sec.

9999
 Sec.

99.99
 min.

999.9
 min.

9999
 min.

99.99
Hour

999.9
Hour

9999
Hour

  ConF.

   4

 ConF.

  1

  ConF.

   2

  ConF.

   5

  ConF.

   6

  ConF.

   7

  ConF.

   8

outP.     
typE    

MEm.

SEt

I

N

P

T

o

P

T

i

.

O

u

T

P

O

P

T

i

.

d

i

s

P

o

P

T

i

.

InP.o.
SECU.    

diS.o.
SECU.

 def.
 SEt

Out.o.
SECU.

nonE

Prog.

no

Prog.
yES

nonE

Prog.

no

Prog.
yES

nonE

no

Prog.

no

yes

Prog.
yES

SECU.
codE

1111

no

PAnE.
r.SEt

r.SEt
inP.t.

S

E

C

U

o

P

T

i

.

TimE.
r.SEt

PnP

nPn

SEnS.
tyPE

Up

dn.

Time.
dir.

  ConF.

3

   

no

yes

 Bot.
DiSP.

BASE

 Set

  ConF.

   9

both

PARAMETER TABLE

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

ENDA

TM

Summary of Contents for ENDA ETM742

Page 1: ...TECHNICAL SPECIFICATIONS 80 up to 31 decreasing linearly 50 at 40 C C According to EN 60529 Front panel IP65 Rear panel IP20 Do not use the device in locations subject to corrosive and flammable gases Supply 230V AC 10 20 50 60Hz 10 30V DC 8 24V AC SMPS Power consumption Max 7VA 2 5mm screw terminal connections Wiring Date retention EMC Safety requirements EN 61326 1 1997 A1 1998 A2 2001 Performan...

Page 2: ...ing run and programming modes Parameter selection key during programming mode 6 Parameter selection and reset key during programing mode Decrement key during run and programming mode 7 Used for selecting options or digits to be changed 8 Used for selecting run or programming modes or for adjusting the parameter One red LED Micro switch 2 SV display Character height 3 Output LED 4 5 6 7 Keypad 1 PV...

Page 3: ...tion Prog yES Prog yES Prog yES No menu is seen No menu is seen No menu is seen Timer can not be reset Both RESET input and the key can be used for resetting See NOT 2 for modification See NOT 2 for modification See NOT 2 for modification Menu is seen but can not be programmed Menu is seen and programming is possible Menu is seen but can not be programmed Menu is seen and programming is possible M...

Page 4: ...ART becomes passive timer stops and initial conditions are returned NOTE if Gate input becomes active timer enters into wait mode Timer waits at that condition until gate input becomes passive Without memory With memory TON Relay On time TOFF Relay Off time t Partial time of TON or TOFF Indefinite time While the device is energized If START input is active first TON and then TOFF times are passed ...

Page 5: ... Fuse F 100 mA 250V AC RESET START GATE NOTE FOR PNP SENSOR TYPE ACTIVE LEVEL IS AUXILIARY POWER SUPPLY VOLTAGE NPN PROXIMITY SWITCH GND OUT active level GND 12V OUT active level is sensor supply voltage GND 230V AC LV Supply Switch Cable size 1 5mm Fuse F 100 mA 250V AC RESET START GATE 230V AC LV Supply Switch Cable size 1 5mm Fuse F 100 mA 250V AC SİSEL MÜHENDİSLİK ELEKTRONİK SAN VE TİC A Ş Şer...

Reviews: