Run mode
Depending on the value of the parameter
bottom display shows time unit or one of the
set values
(
)
.
Ton
or
Toff
OutP.
oPtý.
dýsP.
oPtý.
SECU.
oPtý.
Sensor type can be selected as
nPn
or
PnP
This selection affects all 3 inputs.
See NOTE 2 for modification.
OutP.
typE
mEm.
Set.
There are 9 different output types.
O
utput types are at the next page.
See NOTE 2 for modification.
Device can be operated with memory or
without memory modes for 9 output types.
See NOTE 2 for modification.
Bot.
DÝSP.
Bottom display value can be selected.
If
BASE
is selected, one of the time units
(
Sec. Min
Hour
)
is displayed.
If
Set
is selected,
Ton
or
Toff
value is
displayed.
See NOTE 2 for modification.
WARNING:
As the selected time interval changes
by parameter, time unit also changes.
,
.
or
ýnP.o.
SECU.
Out.o.
SECU.
dýs.o.
SECU.
SECU.
codE
Time.
r.SEt
def.
SEt
Counting direction can be selected as
Up
or
dn.
See NOTE 2 for modification.
Minimum On and Off times for the pulses of
the external inputs (RESET, START and GATE)
can be selected. This selection affects all 3 inputs.
See NOTE 2 for modification.
There are 9 different time intervals.
They are
0-99.99s, 0-999.9s, 0-9999s
0-99.99min, 0-999.9min, 0-9999min
0-99.99h, 0-999.9h and 0-9999h.
Warning
: Changing this parameter
affects the values of
Ton
ve
Toff
.
See NOTE 2 for modification.
29.8
200.0
Ton
or
Toff
See NOTE 1 for adjusting the set value.
Bot.
DiSP
.
Set
Time
bAsE
Time
bAsE
Sens.
TYPE
týmE.
Dir.
puls
time
ýnPt.
oPtý.
Bot.
DiSP.
29.8
Sec.
Toff
200.0
PRESET
SET
PRG
Ton
100.0
BASE
ETM742-EN-08-220103
SET
if key is pressed while holding key, the
programming mode is enabled.
Access code for entering security option menu.
This parameter should be
1111
.
See NOTE 2 for modification.
Prog.
yES
Prog.
yES
Prog.
yES
= No menu is seen.
= No menu is seen.
= No menu is seen.
= Timer can not be reset.
= Both RESET input and the key can
be used for resetting.
See NOT 2. for modification.
See NOT 2. for modification.
See NOT 2. for modification.
= Menu is seen but can not be programmed.
= Menu is seen and programming is possible.
= Menu is seen but can not be programmed.
= Menu is seen and programming is possible.
= Menu is seen but can not be programmed.
= Menu is seen and programming is possible.
nonE
nonE
nonE
no
Prog.
no
Prog.
no
Prog.
no
both
= Timer can be reset by key.
= Timer can be reset by the RESET input.
See NOT 2. for modification.
PAnE.
r.SEt
r.SEt
inP.t.
While leaving the programming mode,
no
= All the modifications are saved.
Yes
=Default values are set to parameters.
See NOT 2. for modification.
PARAMETER MODIFICATION DIAGRAM
NOTE 1
NOTE 2
While holding key in the run mode,
toff
parameters appear. By using keys ,
the value can be adjusted.
ton
and
While holding key, parameters of the menu can be changed by using keys.
3/5
PRESET
PRESET
PRESET
PRESET
PRESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
SET
PRESET
0.010
sec.
0.020
sec.
0.050
sec.
0.100
sec.
0.005
sec.
tImE
bA5E
Puls
timE
99.99
Sec.
999.9
Sec.
9999
Sec.
99.99
min.
999.9
min.
9999
min.
99.99
Hour
999.9
Hour
9999
Hour
ConF.
4
ConF.
1
ConF.
2
ConF.
5
ConF.
6
ConF.
7
ConF.
8
outP.
typE
MEm.
SEt
I
N
P
T
.
o
P
T
i
.
O
u
T
P
.
O
P
T
i
.
d
i
s
P
.
o
P
T
i
.
InP.o.
SECU.
diS.o.
SECU.
def.
SEt
Out.o.
SECU.
nonE
Prog.
no
Prog.
yES
nonE
Prog.
no
Prog.
yES
nonE
no
Prog.
no
yes
Prog.
yES
SECU.
codE
1111
no
PAnE.
r.SEt
r.SEt
inP.t.
S
E
C
U
.
o
P
T
i
.
TimE.
r.SEt
PnP
nPn
SEnS.
tyPE
Up
dn.
Time.
dir.
ConF.
3
no
yes
Bot.
DiSP.
BASE
Set
ConF.
9
both
PARAMETER TABLE