39
|
P a g e
Archimede Portable Dataloggers User Manual
rev.5 -03.12.2019-
You may also view data in graphical form, for inclinometer and T-REX tests: just press
ENTER
when
the table is displayed.
When the last read for the current run has been performed, the DL will display again the list of the
runs with the next run (
corresponding run
) preselected. It is also possible to select “save and exit”
to stop early the runs.
When performing an inclinometer test the screen looks as follows:
The top blue box displays the
Check Sum values
for both channels. These are the semi-sums of the
value read for the channel in the current run and in the corresponding run (A1B1 for A3B3 and
A2B2 for A4B4) at the current level, that is:
The readings of the corresponding runs should have almost identical values with an opposite sign,
so when the second of the corresponding run is performed, the check-sum values could be near to
zero. These values are available only when the corresponding reading has already been done.
On the right part of this box the
Current groove
is shown.
The bottom blue box shows the
Reference values
, that are the values read in the same run and at
the same depth of the reference test and, on the right, the
Current level
in the tube.
At the center are shown the current read values.
The color of the unit of measurement shown in the left part of the screen alternates from black to
blue every time reading values are updated.
PROBE NAME
DATE AND TIME
MEASURE UNIT
REFERENCE VALUES
CURRENT LEVEL
TEST NAME
CURRENT GROOVE
CHECK SUM VALUES