background image

MC1000e-R / T

www.siskiyou.com 

siskiyou

 1-877-313-6418

6

User’s Manual

5.0 Operation

When the MC1000e-R/T has been correctly installed, the user can begin use 

of the system. The operation may be bench tested prior to installing the unit to 
an experiment.

When the user rotates one of the drive axis knobs, the motor drive that is 

plugged into the respective port will also move. For example, if the tilt axis is 
plugged into port 1, when Drive Axis No.1 is rotated, the tilt axis will move.

The targeting axis is set to Drive Axis No.1. To set a point of reference when 

axis 1 is in a desired position, push the TARGET SET button. To retract the 
motorized axis 1, push the RETRACT button. Once the axis has reached its 
reverse limit switch, the red LED will light up. To bring the axis back to the target 
position, push the TARGET button. When the green LED lights up, the motor-
ized axis is in the target position.

For best results and to avoid backlash, the direction of travel when the target 

set button is pushed should be a forward move. This is the same travel direction 
as the movement from the limit switch to the target.

Avoid turning on the dials during the targeting operation, as this may cause 

the stage to “jump” when the targeted position has been reached.

!

2

TARGET:

 This is a black push button that is located in front of Drive Axis 

No.1 and only affects axis 1. 

When a target is set, and the user has pressed the RETRACT button, the user 
can press the TARGET button, and the motor drive will return to the targeted 
position. A green LED will become illuminated when the motor drive has 
reached the targeted position. This feature will only work when the drive axis 
is retracted.

Low/High Speed:

  The low/high speed switch is located on the back of the 

controlled and is labeled with a rabbit

on one side, and a turtle

on the 

opposite. When the switch is toward the turtle, the motor drive will move at a 
slower rate per turn on the drive axis. When the switch is facing the rabbit, the 
motor drive will move at a faster rate per turn on the drive axis. 

25 Pin Connector:

  This connection port is used to connect the controller to 

the junction box. Only use the supplied cable for this connection.

Reverse Polarity:

  On the back of the controller are four toggle switches 

that are labeled 1 through 4 that correspond to the respective drive axes. By 
switching one of the toggle switches, the user is able to change the direction 
the motor drive travels while still rotating the drive axis in the same direction.

4.2 Controller  continued

Summary of Contents for MC1000e-R

Page 1: ...User s Manual siskiyou An Oregon Corporation 2013 by Siskiyou Corporation MC1000e R T Motion Controller ...

Page 2: ...s of the initial invoice date 60 days outside of the US but are subject to a 25 restocking fee Warranty Repairs Before shipping a part to Siskiyou Corporation a Return Authorization RA number must be obtained by calling our ser vice department at our toll free telephone number The product must be shipped prepaid in the original or equivalent packing with the RA number clearly marked on the outside...

Page 3: ...M The slow setting is set to maximize resolution 0 2 µm but still allow coarse position ing 45 µm second The TARGET RETRACT allows the user to set a target location at a desired point When it becomes necessary to back away from the experiment area the user simply depresses the RETRACT button on the controller The stage actua tor plugged into that axis No 1 then automatically retracts to its full n...

Page 4: ... junction box and attach the free end of the wire to a metal surface outside of the system The lug to use is labeled by the electrical symbol for ground 1524 76 1 15 8 siskiyou PO WER ON PO WER IN 1 2 3 4 1 2 3 4 MC1000e R T CONTROLLER COM PATIBLEWITH 76 1 GE ARHEAD CO NTRO LLER BB 5 0 construction rail and hardware used for mounting control and junction boxes if needed 4 screws provided BB 5 0 pu...

Page 5: ...3 and 4 These four knobs are color coded for easier identification for the user and each axis is label with a 1 2 3 or 4 When the controller is plugged into the junction box drive axes 1 2 3 and 4 control the respective axis that is plugged into the junction box TARGET SET This in the red push button that is located in front of Drive Axis No 1 and only affects axis 1 When the user has found a refe...

Page 6: ...ting operation as this may cause the stage to jump when the targeted position has been reached 2 TARGET This is a black push button that is located in front of Drive Axis No 1 and only affects axis 1 When a target is set and the user has pressed the RETRACT button the user can press the TARGET button and the motor drive will return to the targeted position A green LED will become illuminated when ...

Page 7: ...tract function Once retracted the user can press the TARGET button to return to the previous target The system was turned off Will I still have my previous target Yes The system has an onboard memory that stores the location of the last tar get used on axis 1 By placing the drive axis in the retracted mode the user can press the TARGET button to return to the previous target It is recommended to n...

Page 8: ... box for each added microma nipulator or motor drive group up to four per group Junction boxes must be purchased separately SB MC1000e Series A37 Digital Readout The DR1000 Digital Readout provides an accurate highly visible display for axis position The digital readout may be installed on any of our e series controllers and is connected in series via a double sided connector between the controlle...

Page 9: ...ompany ________________________________________ Return Authorization No ______________________________ Note Call the toll free number prior to returning the item Address ________________________________________ City St Zip ________________________________________ Date ______________________________________________ Country ________________________________________ Technical Contact _________________...

Page 10: ...ves 2014 35 EU The Low Voltage Directive and its amending directives 2014 30 EU The Electromagnetic Compatibility Directive and its amending directives 2006 42 EC The Machinery Directive and its amending directives 2011 65 EU Restriction of use of certain hazardous substances RoHS I hereby declare that the equipment above has been designed and found to comply with the relevant sections of the abov...

Page 11: ...ervice sales siskiyou com service siskiyou com telephone toll free 1 877 313 6418 Technical Assistance tech siskiyou com telephone 1 541 479 8697 facsimile 1 541 479 3314 Website www siskiyou com webmaster siskiyou com International Please call or visit our website for international contacts Document No MC1000e R T0613 Printed in the U S A Photos by Robert Jaffe email rob robjaffe com Oregon 7 eps...

Page 12: ...Siskiyou Corporation 110 SW Booth Street Grants Pass OR 97526 2410 Telephone 541 479 8697 Toll Free 877 313 6418 Facsimile 541 479 3314 Website www siskiyou com ...

Reviews: