SIT La Precisa spa
Electronics R& D
Viale dell’Industria 31-33
Preliminary
35129 Padova (Italy)
Doc. n.
Rev.
Date
Page
:
:
:
:
OIM09039
01
24/06/09
10 of 13
- CONFIDENTIAL -
The content of this document is property of SIT La Precisa that reserves to itself all the rights sanctioned by laws.
OIM09114_01 - User Manual (1).doc
9.3
Automatic/Manual mode selection
Quick description: press “B” key
With stove lighted, by pressing “B” key the operational mode is switched from manual to automatic (see
par. 4) and vice versa.
When automatic mode is active, the display shows the SET temperature value and the “AUTO” icon.
When manual mode is active, the display shows the “MAN” icon, the flame’s icon
and the actually
set flame level. If level 5 is currently active, the icon “MAX” below the flame’s icon appears
9.4
Manual mode burner level selection
Quick description: press “C” key
Press “C” (“UP” and “DOWN”) key to move upward and downward in burner flame’s level. The
operation is not cyclic.
In manual mode it’s not possible to have a flame level lower than level 1.
9.5
Automatic mode operation
When automatic mode is selected, the remote checks the room temperature by mean of an internal NTC at
a fixed time interval. Depending on the difference between set room temperature and actual room
temperature, the remote proceeds to modulate the flame increasing or decreasing the flame level with 1
level’s step.
The remote modulates the flame by means of RF signals at 315MHz.
10.
Menu navigation
Quick description: by “D” key pressure.
By pressing “D” key, it’s possible to move sequentially to the accessory functions “fan level”,“sleep” and
“program”, in this order; with a further pressure of “D” key the display operation comes back to the active
operational mode
If no key is pressed within 7 seconds from the menu navigation’s activation, the display comes back to
the active operational mode.