background image

 

20 

10.

 

   Declaration of Conformity EC 

 

 

Unit produced in the factory of: 

 

S.I.T.A. 

Italian Company for Water Treatment 

 
 
 

EC DECLARATION OF CONFORMITY 

 

The undersigned hereby declares, under full responsibility, that the unit: 

 

 

UV STERILIZER 

 

 

SINGLE-MULTILAMP SERIES 

 
 

AL

2

  MODELS 

 
 

                        

IS IN COMPLIANCE WITH 

 

• 

2014/35/UE (low voltage directive) 

• 

2014/30/UE (electro-magnetical compatibility) 

• 

2011/65/UE (RoHS 2) 

• 

2012/19/UE (WEEE) 

• 

IEC -EN 60204-1 norms (safety of machinery-electrical equipment of machinery) 

• 

IEC -EN 55022 norms (characteristics of radio interference) 

• 

D.Lgs. 31/2001 (Implementation of Directive 2015/1787/UE on the quality of 
water intended for human consumption) 

• 

2014/68/UE (art.4 comm.3) (PED) 

 
 
 

 

The validity of CE marking is subordinated to the equipment integrity. Any modification,if not 

authorized,will cancel the use of the CE marking.This will occurs in case the relevant risks have not 

been previously analyzed by our company,and a new EC Declaration of Conformity has been issued. 

Summary of Contents for 405 AL2

Page 1: ...ULTRAVIOLET DISINFECTION EQUIPMENT FOR THE TREATMENT OF DRINKING WATER SINGLE LAMP AL2 SERIES 405C AL2 405 AL2 412 AL2 MANUAL OF INSTALLATION USE AND SERVICING English 08 2019 Rev D ...

Page 2: ...r Installation 8 4 1 4 1 Assembling of the UV chamber 8 4 2 4 2 Detailed drawing of the UV C chamber 8 5 Models drawing 8 4 2 UV chamber drawing 10 6 Electrical scheme 13 7 Display Information Troubleshooting 14 8 Technical data sheet 16 8 1 8 1 UV 405 AL2 16 8 2 UV 405C AL2 17 8 3 UV 412 AL2 18 9 Warranty Conditions 19 10 Declaration of Conformity EC 20 ...

Page 3: ...ion to ensure the safe use of the UV system The operating instructions are an integral part of the equipment supply Before putting into operation all the conditions necessary for safe operation of the equipment must be fulfilled The installation commissioning and maintenance of the equipment should only be carried out by qualified personnel The equipment should only be operated by authorized perso...

Page 4: ... and quality of water treated General directions According to the European rules EN 60204 1 safety of the set up off the electrical equipment general rules the low tension electrical instruments rule 2006 95 CE must be connected to a current tap provided with grounding Safety direction The light of ultra violet lamps can cause serious burns to unprotected skin and eyes therefore it is recommended ...

Page 5: ...buying new equipment of an equivalent type for the purpose of starting the correct recycling disposal Appropriate separate collection for the subsequent start up of the disused equipment for recycling treatment and environmentally compatible disposal helps to avoid possible negative effects on the environment and on health and favors the re use and or recycling of the materials it is composed of t...

Page 6: ...rect working or of anomalies which may occur during the operating of the unit MAINTENANCE The UV System of SINGLE LAMP series have been projected and realized by S I T A Srl with simple and functional principles which make the checking procedures and the periodical servicing particularly easy The main points which characterize the ordinary servicing are the following check quarterly the quartz sle...

Page 7: ... it with a cloth soaked with an acid solution such as vinegar or lemmon 5 reassemble the sleeve being sure to center the guide spring fixed on the bottom put the o ring on the quartz sleeve then tighten the sleeve bolt place the o ring in the seat of the sleeve bolt insert the sleeve inside it till it leans then screw on the S S chamber 6 turn on water checking for eventual leaks 7 remount the lam...

Page 8: ...7 3 1 3 1 Installation scheme recommended ...

Page 9: ... Collegare il quadripin elettrico Avvitare il bloccaguaina in nylon Inserire la molla di appoggio della lampada nella guaina al quarzo Insert the quartz sleeve paying attention in centering the guide spring placed ASSEMBLING OF THE UV C CHAMBER Insert the O RING on the sleeve on the bottom of the chamber Unscrew the nylon sleeve bolt Extract the PVC contact cover ...

Page 10: ...ctivate the lamp life count down hour meter see display description In case of LCD PLUS system with UV sensor then operate the sensor calibration This operation must be done after at least 5 minutes from lamp start with quartz sleeve clean with sensor measuring window clean and with steady water flow Inserire la lampada UV C nella guaina Collegare il quadripin elettrico Inserire la calotta PVC cop...

Page 11: ...LA CONTACT COVER COPRICONTATTO G FOUR PIN HOLDER QUADRIPIN O RING 23x4 O RING 23x4 C D F E BALLAST SCHUKO U K H H L 028060D 028036 028061 028088 028034 K 2753 028034D 2753 YZ 3 IN 2 D OUT 1 C B A SPINA U K SU RICHIESTA SPINA SCHUKO STANDARD SENZA SPINA SU RICHIESTA 026427 B CLIP CLIP M 026427 B M M E F G L H N V141 O RING O RING N V141 028102C 028103C 028060D 028036 028061 028088 028034 K 2753 028...

Page 12: ...11 5 Models drawing ...

Page 13: ...12 ...

Page 14: ...13 6 Electrical scheme ...

Page 15: ... the working days count down replace the lamp and press and hold for less than 5 seconds the button The value of the days meter will start to flash Within 5 sec press again the button to confirm the days meter reset ATTENTION Do not replace the lamp with powered panel Press and hold for more than 9 seconds the button to silence the alarm for 7 days max 4 times Working days count down lamp exhaust ...

Page 16: ...r reset ATTENTION Do not replace the lamp with powered panel Press and hold for more than 9 seconds the button to silence the alarm for 7 days max 4 times Working days count down Alarm Buzzer Remaining working days of the lamp Keep pressed for less than 5 sec The value of the days meter will start to flash Within 5 sec press again the button to confirm the days meter reset N B if within 5 sec it i...

Page 17: ... 10 bars g Protection class IP 54 Shape U Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 30 W Type Low pressure type 028102 CONTROL PANEL AL2 Material Thermoplastic Dimensions 118 x 60 x 64 mm Protection class IP 54 Ambient temperature range 5 45 C Power supply 230 V 50 60 Hz Lamp cable length 1 m Power supply cable 1 m Feed plug SCHUKO UK or passing wires Monitor d...

Page 18: ...rotection class IP 54 Shape U Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 30 W Type Low pressure type 028102C CONTROL PANEL AL2 Material Thermoplastic Dimensions 118 x 60 x 64 mm Protection class IP 54 Ambient temperature range 5 45 C Power supply 230 V 50 60 Hz Lamp cable length 1 m Power supply cable 1 m Feed plug SCHUKO UK or passing wires Monitor display Digi...

Page 19: ...Protection class IP 55 Shape U Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 40 W Type Low pressure type 028104 CONTROL PANEL AL2 Material Thermoplastic Dimensions 118 x 60 x 64 mm Protection class IP 54 Ambient temperature range 5 45 C Power supply 230 V 50 60 Hz Lamp cable length 1 m Power supply cable 1 m Feed plug SCHUKO UK or passing wires Monitor display Digi...

Page 20: ...ver the product repaired or tampered by non authorized third parties and the product on which an intervention has been made for defect of for convenience tests is excluded from the warranty Repairs are normally carried out in SITA warehouse or in authorized after sales service centers signalled by SITA The warranty does not cover 1 Accidental breakages due to the transport 2 Breakages due to the u...

Page 21: ...2 2012 19 UE WEEE IEC EN 60204 1 norms safety of machinery electrical equipment of machinery IEC EN 55022 norms characteristics of radio interference D Lgs 31 2001 Implementation of Directive 2015 1787 UE on the quality of water intended for human consumption 2014 68 UE art 4 comm 3 PED The validity of CE marking is subordinated to the equipment integrity Any modification if not authorized will ca...

Reviews: