3.

 

  Instruction for installation and setting at work 

 

General premise: 

The installation of the  SINGLE LAMP sterilization units must be carried out 

by  specialized  staff,  scrupolously  following  the  instructions  hereby given. It  has  been moreover 
considered necessary to give some general information about the electrical and water connections. 

Cautions: 

check that the UV panel is not connected to the power supply and that the tap of the 

water to be treated is turned off. 

Connect the delivery of the water to be treated to the special water connection  

Turn on water and check for possible leaks in any part of the unit 

Connect the plug to the current tap 

Check that the disinfected water comes out and that the LEDS on the panel of the control board, 

signal the correct working 
Let the disinfected water flow down to outlet for at least 10 minutes before using it, in order to 
make the possible impurities present in the unit drain out. 
NOTE:  it  is  recommended  to  install  a  water  filter  directly  before  the  UV  sterilizer  in  order  to 
remove the suspended particles, eventually present  in  the water to  be treated, which could limit 
the efficiency of sterilization. 

CHECKS 

The SINGLE LAMP UV System is ready for producing disinfected water, once the connection to 
the water system and to the electrical grid is carried out. The unit works automatically, the 
electronical boards which control the signals reaching the control panel, allow the visualization 
(or the sonorization) of the correct working or of anomalies which may occur during the operating 
of the unit. 

MAINTENANCE 

The UV System of  SINGLE LAMP series have been projected and realized by S.I.T.A. Srl with 
simple and functional principles which make the checking procedures and the periodical servicing 
particularly easy. 
The main points which characterize the ordinary servicing are the following:  check quarterly the 
quartz sleeves, which contain the UV lamps, in order to ensure the maximum disinfection, for the 
cleaning. 
Maintenance  work  may  only  be carried out  by personnel  who have been trained and authorized 
for this work by the owner and/or user. The owner and/or user must ensure that the maintenance 
personnel  are familiar with  the safety measures and regulations,  and that they also  comply with 
them, in addition to having read and understood the operating instructions.  
Only 

original 

replacement 

parts 

from 

the 

supplier 

must 

be 

used. 

The following are the recommended service intervals for replacement parts: 
UV lamp change - once per 9000 hours.                                                                                                                                    
UV quartz sleeve clean - frequency depends on the quality of the water. 
O-ring for quartz sleeve-once per year. 

 

Procedure for the UV lamp replacement (9000 h max.) 

 

1) disconnect the electrical box from the electrical grid 

 

2) lift the cover slightly turning, carefully loosen the electrical 4-pins connection, and extract the 

 

lamp from the quartz sleeve 

 

3) remove the lamp from the packing, handling it carefully by its ends 

 

4) insert the new lamp into the quartz sleeve of the UV System 

 

5) connect the lamp to the electrical connection and put again the cover 

 

6) connect again the equipment. 

 

N.B. for the replacement of the lamp it is not necessary to turn water off 

Summary of Contents for 405 AL2

Page 1: ...ULTRAVIOLET DISINFECTION EQUIPMENT FOR THE TREATMENT OF DRINKING WATER SINGLE LAMP AL2 SERIES 405C AL2 405 AL2 412 AL2 MANUAL OF INSTALLATION USE AND SERVICING English 08 2019 Rev D ...

Page 2: ...r Installation 8 4 1 4 1 Assembling of the UV chamber 8 4 2 4 2 Detailed drawing of the UV C chamber 8 5 Models drawing 8 4 2 UV chamber drawing 10 6 Electrical scheme 13 7 Display Information Troubleshooting 14 8 Technical data sheet 16 8 1 8 1 UV 405 AL2 16 8 2 UV 405C AL2 17 8 3 UV 412 AL2 18 9 Warranty Conditions 19 10 Declaration of Conformity EC 20 ...

Page 3: ...ion to ensure the safe use of the UV system The operating instructions are an integral part of the equipment supply Before putting into operation all the conditions necessary for safe operation of the equipment must be fulfilled The installation commissioning and maintenance of the equipment should only be carried out by qualified personnel The equipment should only be operated by authorized perso...

Page 4: ... and quality of water treated General directions According to the European rules EN 60204 1 safety of the set up off the electrical equipment general rules the low tension electrical instruments rule 2006 95 CE must be connected to a current tap provided with grounding Safety direction The light of ultra violet lamps can cause serious burns to unprotected skin and eyes therefore it is recommended ...

Page 5: ...buying new equipment of an equivalent type for the purpose of starting the correct recycling disposal Appropriate separate collection for the subsequent start up of the disused equipment for recycling treatment and environmentally compatible disposal helps to avoid possible negative effects on the environment and on health and favors the re use and or recycling of the materials it is composed of t...

Page 6: ...rect working or of anomalies which may occur during the operating of the unit MAINTENANCE The UV System of SINGLE LAMP series have been projected and realized by S I T A Srl with simple and functional principles which make the checking procedures and the periodical servicing particularly easy The main points which characterize the ordinary servicing are the following check quarterly the quartz sle...

Page 7: ... it with a cloth soaked with an acid solution such as vinegar or lemmon 5 reassemble the sleeve being sure to center the guide spring fixed on the bottom put the o ring on the quartz sleeve then tighten the sleeve bolt place the o ring in the seat of the sleeve bolt insert the sleeve inside it till it leans then screw on the S S chamber 6 turn on water checking for eventual leaks 7 remount the lam...

Page 8: ...7 3 1 3 1 Installation scheme recommended ...

Page 9: ... Collegare il quadripin elettrico Avvitare il bloccaguaina in nylon Inserire la molla di appoggio della lampada nella guaina al quarzo Insert the quartz sleeve paying attention in centering the guide spring placed ASSEMBLING OF THE UV C CHAMBER Insert the O RING on the sleeve on the bottom of the chamber Unscrew the nylon sleeve bolt Extract the PVC contact cover ...

Page 10: ...ctivate the lamp life count down hour meter see display description In case of LCD PLUS system with UV sensor then operate the sensor calibration This operation must be done after at least 5 minutes from lamp start with quartz sleeve clean with sensor measuring window clean and with steady water flow Inserire la lampada UV C nella guaina Collegare il quadripin elettrico Inserire la calotta PVC cop...

Page 11: ...LA CONTACT COVER COPRICONTATTO G FOUR PIN HOLDER QUADRIPIN O RING 23x4 O RING 23x4 C D F E BALLAST SCHUKO U K H H L 028060D 028036 028061 028088 028034 K 2753 028034D 2753 YZ 3 IN 2 D OUT 1 C B A SPINA U K SU RICHIESTA SPINA SCHUKO STANDARD SENZA SPINA SU RICHIESTA 026427 B CLIP CLIP M 026427 B M M E F G L H N V141 O RING O RING N V141 028102C 028103C 028060D 028036 028061 028088 028034 K 2753 028...

Page 12: ...11 5 Models drawing ...

Page 13: ...12 ...

Page 14: ...13 6 Electrical scheme ...

Page 15: ... the working days count down replace the lamp and press and hold for less than 5 seconds the button The value of the days meter will start to flash Within 5 sec press again the button to confirm the days meter reset ATTENTION Do not replace the lamp with powered panel Press and hold for more than 9 seconds the button to silence the alarm for 7 days max 4 times Working days count down lamp exhaust ...

Page 16: ...r reset ATTENTION Do not replace the lamp with powered panel Press and hold for more than 9 seconds the button to silence the alarm for 7 days max 4 times Working days count down Alarm Buzzer Remaining working days of the lamp Keep pressed for less than 5 sec The value of the days meter will start to flash Within 5 sec press again the button to confirm the days meter reset N B if within 5 sec it i...

Page 17: ... 10 bars g Protection class IP 54 Shape U Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 30 W Type Low pressure type 028102 CONTROL PANEL AL2 Material Thermoplastic Dimensions 118 x 60 x 64 mm Protection class IP 54 Ambient temperature range 5 45 C Power supply 230 V 50 60 Hz Lamp cable length 1 m Power supply cable 1 m Feed plug SCHUKO UK or passing wires Monitor d...

Page 18: ...rotection class IP 54 Shape U Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 30 W Type Low pressure type 028102C CONTROL PANEL AL2 Material Thermoplastic Dimensions 118 x 60 x 64 mm Protection class IP 54 Ambient temperature range 5 45 C Power supply 230 V 50 60 Hz Lamp cable length 1 m Power supply cable 1 m Feed plug SCHUKO UK or passing wires Monitor display Digi...

Page 19: ...Protection class IP 55 Shape U Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 40 W Type Low pressure type 028104 CONTROL PANEL AL2 Material Thermoplastic Dimensions 118 x 60 x 64 mm Protection class IP 54 Ambient temperature range 5 45 C Power supply 230 V 50 60 Hz Lamp cable length 1 m Power supply cable 1 m Feed plug SCHUKO UK or passing wires Monitor display Digi...

Page 20: ...ver the product repaired or tampered by non authorized third parties and the product on which an intervention has been made for defect of for convenience tests is excluded from the warranty Repairs are normally carried out in SITA warehouse or in authorized after sales service centers signalled by SITA The warranty does not cover 1 Accidental breakages due to the transport 2 Breakages due to the u...

Page 21: ...2 2012 19 UE WEEE IEC EN 60204 1 norms safety of machinery electrical equipment of machinery IEC EN 55022 norms characteristics of radio interference D Lgs 31 2001 Implementation of Directive 2015 1787 UE on the quality of water intended for human consumption 2014 68 UE art 4 comm 3 PED The validity of CE marking is subordinated to the equipment integrity Any modification if not authorized will ca...

Reviews: