CAUTION
Risk of injury by moving parts in the interior of the housing!
Ü
Do not reach through the openings in the housing.
Follow this procedure:
1. Remove the cap from pressure port L.
2. Connect a temporary pressure supply to pressure port L.
3. Apply the operating pressure to pressure port L (see name plate).
4. Insert the clamping rod with care, so that the wipers in the rod openings
are not damaged.
7.2 Attach Safety Lock
WARNING
Risk of injury by dropping!
Clamping the rod by the Safety Lock is not a safe method of transport, and
might cause danger possibly resulting in serious injury and damage to assets.
Ü
Secure the Safety Lock and clamping rod separately.
Ü
Secure the Safety Lock and clamping rod by suitable means before and
during mounting.
If the
rod is rigidly
attached, mount the Safety Lock with a radially loose
spring base. You can find SITEMA spring bases in “Technical data sheet TI-
B20.”
If the
rod is loosely
attached (such as by suspension of the rod as a radial
loose bearing), fix the Safety Lock rigidly (screw directly).
To fix the Safety Lock use only the threads or holes on the mounting side -
see
10].
Operating Manual
Safety Locks series KRGP
Pneumatic / compressive load
Original instructions BA-S12-en-1-15
© SITEMA GmbH & Co. KG . G.-Braun-Straße 13 . 76187 Karlsruhe (Germany) . Phone: +49(0)721/98661-0 . Fax: -11 . www.sitema.com
17/28