IF  LOST  THE  REMOTE  CONTROLLERS

HOW  CAN 

WE DO

 

If you lost the remote controller,you can use the memory to erase its control 
right.But  it  will  erase  all  the  others  remote  controllers

s  control 

right.therefore,after  erased,All  the  remote  controllers  need  study  again.we 
suggest  if  lost  one  remote  controller,please  erase  the  memory  of  all  the 
remote  controllers,of  course,if  you  think  it  is  complicated,you  just  don

t  do 

this,the other remote controllers also can use.Please see below how to erase 
the memory: 

 

1

Pull out the AC adaptor 

2

Use the screwdriver to take the system from the wall,open the crust,please 

take care of the screws. 
3

Finding out the dail switch on the main control circuitry board

see figure4

4

Dail the WORK code to

O

,study code to

N

,it will turn into the deactivated 

status,meanwhile,the study light will be yellow. 
5

Press any button on the remote controller,it beep 2 times and the study 

light  will  be  green,it  indicate  to  erase  the  control  right  of  the  remote 
controller.repeat again to erase the control right of all the remote controllers. 
6

Refer to 2.2 to study all the remote controllers. 

7

Fold the top and bottom cover,fix the system on the wall. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GS901

Page 1: ...Wireless pepper spray system GS901 Installation Guide Please read this guide carefully and keep it in a safe place ...

Page 2: ...e the system in the surveillance mode if the unpermissive person enter into the first sensor surveillance area the system will automatically alarm if the unpermissiv e person enter into the second sensor surveillance area the system will automatical ly spray the pepper 3 Pepper in the system introduction Our pepper ingredient used natural strong stimulated ingredient such as purely extractive pepp...

Page 3: ...ust is made from ABS plastic please take care while in Carrying and installing don t let the unit fall down or kick down 2 while installing please do it strictly according to this manual to avoid the pepper spray out in case of the pepper sprayed on the face please keep calm close the system and pull out the power use the clear water to clean out then clean by 2 soda water after 20 minutes you wil...

Page 4: ...3 PRODUCT INTRODUCTION CHART Figure 1 Figure 2 ...

Page 5: ...itive wire into the battery positive head Attention before connected to the battery please put the 2 remote controllers in a safety place to avoid to open the system while in installing Figure 3 Optional function before installation Figure 4 ...

Page 6: ... can t control the system the remote controllers you can buy from our distribution 2 2 Study procedure 2 21 Please find the dial switch on the main control circuitry board it had 2 dial code on the dial switch it is work and study code please dial work code to 1 dail study code to N it indicate the system turn into the study mode meanwhile you will see the study light will be yellow 2 22 Press any...

Page 7: ...r bell the carrying capacity of JK port is 10A 250 VA connection mode 1 2 is close 2 3 is open OP PORT is the optical port once the system alarm the optical port will open it can use as driver signal to the other alarm systems the carrying capacity of OP port is 50MA 24V Tips if you feel the above functions don t need to use please don t touch the main control circuitry board direct to the next st...

Page 8: ...etect it s surveillance place whether have people within 10m if have it will automatically alarm meanwhile open the second sensor to detector whether have people within 1 meters if have it will automatically spray the pepper see figure6 please take care when test Figure6 2 Deactivated alarm and close the system Once the system is in warm up surveillance mode alarm mode Press the OFF button it will...

Page 9: ...ance mode 4 Alarm stutas Once it alarms the working light will flash every 2 seconds meanwhile open the second sensor to detector whether have people within 1 meters if have it will automatically spray the pepper after 5 minutes it will automatically turn into surveillance mode then close the second sensor of course you can press the OFF button on the remote controller to deactivate WORKING LIGHT ...

Page 10: ...w to erase the memory 1 Pull out the AC adaptor 2 Use the screwdriver to take the system from the wall open the crust please take care of the screws 3 Finding out the dail switch on the main control circuitry board see figure4 4 Dail the WORK code to O study code to N it will turn into the deactivated status meanwhile the study light will be yellow 5 Press any button on the remote controller it be...

Page 11: ... alert power 100 dB Detection way Digital infra red pluse and PIR Operation temperature 30 60 The spray distance of the pepper canister 3m The spray speed of the pepper canister 8 5ml s Capacity of the pepper canister 300ml power supply alarm Battery 12V 2Ah adaptor remote control 12V 23A Operation current Surveillance mode 10 mA Alarm status 250 mA Spray the pepper 2A ...

Reviews: