WARNING:

 

To  prevent  injury,  this  unit must  be  securely  attached  to  the 

ceiling in accordance with the installation instructions. 

Manufacturer: 

 

Siterwell Electronics CO., Limited 
No.666 Qingfeng Road, Jiangbei District, Ningbo, 

Zhejiang Province

China 

TEL: 0086-574-87729581 

FAX: 0086-574-87729581 

E-MAIL:Sales@china-siter.com 

Summary of Contents for GS536G

Page 1: ...h bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm device at each end install a smoke alarm device at the top of a first to second floor stairwell Important Safety Information 1 The test button accurately tests smoke alarm device functions Do not use any other test method Test smoke alarm device weekly to ensur...

Page 2: ...elps from the section trouble shooting WARNING Test the alarm for correct operation using the test facility whenever the battery is replaced Diagram 3 Do Not Install Smoke alarm devices in the Following Places 1 Near appliances or areas where normal combustion Regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarm device with unwanted alarm control for this areas 2 I...

Page 3: ... can return to your retailer IMPORTANT Do not attempt to remove the cover to clean inside This will affect warranty Repair Caution Do not attempt to repair the alarm It will affect your warranty If the alarm is not operating properly and is still under warranty return it to the original place you buy Pack it in a well padded carton and ship to the original place you buy If the alarm is no longer u...

Page 4: ...ture house let the alarm induce every corner Install an alarm in every bedroom If alarm couldn t be installed in the middle of the ceiling for some reasons the distance which the alarm away from the wall corner should be beyond 50cm see Diagram 6 Put smoke alarm at both ends of a bedroom hallway or large room if the hallway or room is more than 9 1 m 30 ft long Install smoke alarms no slopped peak...

Page 5: ...Document NO RD 536G 39 001 Version C 2018 06 19 5 Diagram 4 Diagram 4 Diagram 5 Diagram 5 Diagram 6 ...

Page 6: ... Apply pressure b especially for the edge for at least 10 seconds Please note it is mounted on a stable dry and free of dust area Once assembled the ceiling element cannot be removed or repositioned 2 Assembling the smoke alarm element The smoke alarm element with magnets is mounted on the base of the smoke alarm Remove the protective foil and place it against the base Apply pressure c especially ...

Page 7: ...unit must be securely attached to the ceiling in accordance with the installation instructions Manufacturer Siterwell Electronics CO Limited No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086 574 87729581 FAX 0086 574 87729581 E MAIL Sales china siter com ...