Introduction 

This

 

product

 

can

 

be

 

included

 

and

 

operated

 

in

 

any

 

Z

Wave

 

network

 

with

 

other

 

Z

Wave 

certified

 

devices

 

from

 

other

 

manufacturers

 

and/or

 

other

 

applications.

 

All

 

non

battery 

operated

 

nodes

 

within

 

the

 

network

 

will

 

act

 

as

 

repeaters

 

regardless

 

of

 

vendor

 

to 

increase

 

reliability

 

of

 

the

 

network. 

In

 

the

 

front

 

casing,

 

there

 

is

 

button

 

that

 

is

 

used

 

to

 

carry

 

out

 

adding,

 

remove

 

or

 

reset 

factory

 

default

 

settings

 

on

 

PCB

 

Board. 

When

 

power

 

is

 

first

 

supplied,

 

the

 

LED

 

will

 

flash

 

on

 

and

 

off

 

with

 

yellow

 

alternately

 

every 

1

 

second

 

intervals

 

within

 

5

 

seconds

 

if

 

the

 

detector

 

has

 

not

 

been

 

added

 

a

 

Z

Wave 

network,

 

otherwise

 

the

 

LED

 

will

 

flash

 

on

 

and

 

off

 

5

 

times

 

with

 

cyan

 

alternately

 

every

 

300 

milliseconds.

 

Please

 

get

 

familiar

 

with

 

the

 

terms

 

below

 

before

 

starting

 

the

 

operations. 

This

 

Plug

 

has

 

function

 

that

 

remembers

 

the

 

relay

 

states,

 

the

 

plug

 

will

 

turn

 

on

 

after

 

power 

up

 

next

 

time

 

if

 

the

 

plug

 

is

 

turn

 

on

 

before

 

the

 

power

 

cut

off. 

Manufacture

 

ID:

 

0x0266 

Product

 

ID:

 

0x1087(EU) 

 
 

Technical

 

Parameters   

ON/OFF

 

control  

Compatible

 

with

 

300

 

series

 

and

 

500

 

series  

Measuring

 

voltage,

 

current,

 

instant

 

power,

 

accumulated

 

power.  

Input

 

voltage:

 

110-230V

 

AC

 

​​

 

​​

 

50/60HZ 

Max

 

current:

 

13A  

Rated

 

input

 

current:

 

10A,110-230V

 

​,

50/60

 

Hz

 

​​

 

Continuous

 

load

 

current 

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

16A,110-230V

 

​,

50/60Hz

 

​​

 

Instantaneous

 

load

 

current 

Radio

 

Protocol:

 

Z-Wave 

Radio

 

Frequency:

 

868.4MHz

 

EU;

 

908.4MHz

 

US;

 

921.4MHz

 

ANZ;

 

869.2MHz

 

RU 

Wireless

 

distance

50m 

Operation

 

temperature:

 

0-40

 

Storage

 

temperature:0-60

   

Dimension

 

(D

 

x

 

W

 

x

 

H):  

US

 

plug:

 

43mm

 

x

 

43mm

 

x

 

45mm   

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

EU

 

plug:

 

43mm

 

x

 

43mm

 

x

 

65mm

 

(F

 

Type) 

 
 
 

Product

 

Configuration 

 

Summary of Contents for STW-W3350WU

Page 1: ...nual Power plug Model number STW W3350WU Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Siterwell Technology HK Co LTD ...

Page 2: ...rnately every 300 milliseconds Please get familiar with the terms below before starting the operations This Plug has function that remembers the relay states the plug will turn on after power up next time if the plug is turn on before the power cut off Manufacture ID 0x0266 Product ID 0x1087 EU Technical Parameters ON OFF control Compatible with 300 series and 500 series Measuring voltage current ...

Page 3: ...controller or gateway operating manual 3 Press the button three times within 1 5 second the device will enter exclusion mode And the LED will flash on and off with yellow alternately five times within 2 seconds Note If device has not been added to Z wave network the device will enter adding mode automatically when it is powered on You should let the controller enter adding mode first before power ...

Page 4: ...rgy consumption measuring These measurement results are sent to Z Wave Controller or Z Wave Gateway Voltage The Supply Power Voltage For Plug Current The Current for the Electric Device Connect to Plug Consumption Power Power Consumed by an Electric Device in an Instant unit Watt W Energy Energy Consumed by an Electric Device in a Period Most commonly Measure in Kilowatt hours kWh One kilowatt hou...

Page 5: ...OWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline Red Led will blink every second until current is normal less than Parameter 3 You must remove the loader and turn on the Plug press the button once to enable current monitor and clear NOTIFICATION ALARM This parameter value must be greater than 4 If user set this parameter to default by Configure CC the parameter 4 will be set to...

Page 6: ...r defines the timer function Enable Disable This parameter can be configured with 0 or 1 where 0 means disable time switch function and 1 enable The period will be defined in parameter 9 If this parameter is Set to 1 and when turn the plug relay on the timer in plug start run with time period defined in parameter 9 and the plug will turn the relay off Function Time switch Configure Parameter Numbe...

Page 7: ...ting This configuration is not influenced to OCP monitor and energy accumulated Function Meter Enable Parameter Number 12 Parameter Size 1 Byte Available Settings 0 1 Default Setting 1 LED Color Indicator LED Color Led Display Status Description Pink Blink 5 Times 1s Interval Power on or Reset and Not Add in Z Wave Network Blink 5 Times 500ms Interval Send Node Info when Press Button tripled Blue ...

Page 8: ...CH_ALL V1 COMMAND_CLASS_BASIC V1 SPECIFICATIONS Power Supply AC110 230V 10 50 60Hz Rate Load Current 13A 110 230V 50 60Hz Continuous Load 16A 110 230V 50 60Hz Momentary Load Power Consumption 0 13W EU Standards Compliance Radio Protocol Z Wave Radio Frequency EU 868 4MHz US 908 4MHz Valid Range Up to 60m outdoors Up to 30m indoors Depending on terrain and building structure Operational Temperature...

Reviews: