Product

 

List 

Power

 

plug

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

1pc 

Instruction

 

manual

 

​​

 

​​

 

​​

 

​​

 

​​

 

1pc

 

 
Add

 

Smart

 

Plug

 

to

 

Z

Wave

 

Network 

1.

 

Make

 

sure

 

the

 

sensor

 

is

 

powered. 

2.

 

Set

 

Z-Wave

 

main

 

controller

 

(ex,

 

SiterOne

 

tablet)

 

or

 

Z

Wave

 

gateway

 

into

 

adding 

mode

 

(Refer

 

to

 

the

 

controller

 

or

 

gateway

 

operating

 

manual) 

3.

 

Press

 

the

 

button

 

three

 

times

 

within

 

1.5

 

second,

 

the

 

device

 

will

 

enter

 

adding

 

mode. 

And

 

the

 

LED

 

will

 

flash

 

on

 

and

 

off

 

with

 

green

 

alternately

 

five

 

times

 

within

 

2

 

seconds. 

 
Remove

 

Smart

 

Plug

 

from

 

Z

Wave

 

Network 

1.

 

Make

 

sure

 

the

 

sensor

 

is

 

powered. 

2.

 

Set

 

Z

Wave

 

controller

 

or

 

Z

Wave

 

gateway

 

into

 

remove

 

mode

 

(Refer

 

to

 

the

 

controller 

or

 

gateway

 

operating

 

manual) 

3.

 

Press

 

the

 

button

 

three

 

times

 

within

 

1.5

 

second,

 

the

 

device

 

will

 

enter

 

exclusion

 

mode. 

And

 

the

 

LED

 

will

 

flash

 

on

 

and

 

off

 

with

 

yellow

 

alternately

 

five

 

times

 

within

 

2

 

seconds. 

Note:

 

​​

If

 

device

 

has

 

not

 

been

 

added

 

to

 

Z

wave

 

network,

 

the

 

device

 

will

 

enter

 

adding 

mode

 

automatically

 

when

 

it

 

is

 

powered

 

on.

 

You

 

should

 

let

 

the

 

controller

 

enter

 

adding 

mode

 

first

 

before

 

power

 

on

 

the

 

device

 

to

 

run

 

this

 

function. 

 
Reset

 

Smart

 

Plug

 

to

 

Factory

 

Default 

Reset

 

procedure

 

will

 

delete

 

all

 

information

 

on

 

the

 

Z

Wave

 

network

 

and

 

Z

Wave 

controller

 

or 

Z

Wave

 

Gateway,

 

and

 

restore

 

the

 

sensor

 

to

 

factory

 

default

 

settings. 

1.

 

Make

 

sure

 

the

 

sensor

 

is

 

powered. 

2.

 

Press

 

and

 

hold

 

the

 

button

 

more

 

than

 

10

 

seconds

 

until

 

the

 

LED

 

blink

 

with

 

red

 

color. 

3.

 

Release

 

the

 

button. 

Summary of Contents for STW-W3350WU

Page 1: ...nual Power plug Model number STW W3350WU Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Siterwell Technology HK Co LTD ...

Page 2: ...rnately every 300 milliseconds Please get familiar with the terms below before starting the operations This Plug has function that remembers the relay states the plug will turn on after power up next time if the plug is turn on before the power cut off Manufacture ID 0x0266 Product ID 0x1087 EU Technical Parameters ON OFF control Compatible with 300 series and 500 series Measuring voltage current ...

Page 3: ...controller or gateway operating manual 3 Press the button three times within 1 5 second the device will enter exclusion mode And the LED will flash on and off with yellow alternately five times within 2 seconds Note If device has not been added to Z wave network the device will enter adding mode automatically when it is powered on You should let the controller enter adding mode first before power ...

Page 4: ...rgy consumption measuring These measurement results are sent to Z Wave Controller or Z Wave Gateway Voltage The Supply Power Voltage For Plug Current The Current for the Electric Device Connect to Plug Consumption Power Power Consumed by an Electric Device in an Instant unit Watt W Energy Energy Consumed by an Electric Device in a Period Most commonly Measure in Kilowatt hours kWh One kilowatt hou...

Page 5: ...OWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline Red Led will blink every second until current is normal less than Parameter 3 You must remove the loader and turn on the Plug press the button once to enable current monitor and clear NOTIFICATION ALARM This parameter value must be greater than 4 If user set this parameter to default by Configure CC the parameter 4 will be set to...

Page 6: ...r defines the timer function Enable Disable This parameter can be configured with 0 or 1 where 0 means disable time switch function and 1 enable The period will be defined in parameter 9 If this parameter is Set to 1 and when turn the plug relay on the timer in plug start run with time period defined in parameter 9 and the plug will turn the relay off Function Time switch Configure Parameter Numbe...

Page 7: ...ting This configuration is not influenced to OCP monitor and energy accumulated Function Meter Enable Parameter Number 12 Parameter Size 1 Byte Available Settings 0 1 Default Setting 1 LED Color Indicator LED Color Led Display Status Description Pink Blink 5 Times 1s Interval Power on or Reset and Not Add in Z Wave Network Blink 5 Times 500ms Interval Send Node Info when Press Button tripled Blue ...

Page 8: ...CH_ALL V1 COMMAND_CLASS_BASIC V1 SPECIFICATIONS Power Supply AC110 230V 10 50 60Hz Rate Load Current 13A 110 230V 50 60Hz Continuous Load 16A 110 230V 50 60Hz Momentary Load Power Consumption 0 13W EU Standards Compliance Radio Protocol Z Wave Radio Frequency EU 868 4MHz US 908 4MHz Valid Range Up to 60m outdoors Up to 30m indoors Depending on terrain and building structure Operational Temperature...