background image

 

CC

 

to

 

trigger

 

over

 

current

 

protection.

 

If

 

you

 

set,

 

the

 

wall

 

plug

 

will

 

send 

NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED

 

​​

to

 

lifeline,

 

and 

the

 

wall

 

plug

 

will

 

be

 

turn

 

off,

 

red

 

Led

 

will

 

blink

 

every

 

second.

 

You

 

can

 

press

 

the

 

button 

once

 

to

 

clear

 

this

 

alarm

 

and

 

then

 

the

 

wall

 

plug

 

will

 

be

 

back

 

to

 

normal

 

state. 

Advanced

 

Configuration 

1.

 

Send

 

Meter

 

Report

 

Enable. 

This

 

parameter

 

defines

 

Disable/Enable

 

meter

 

report

 

measure

 

data

 

to

 

controller.

 

​​

This 

setting

 

is

 

not

 

influenced

 

configuration

 

No.

 

6. 

Function:

 

​​

Meter

 

Report

 

Enable 

Parameter

 

Number:

 

​​

1. 

Parameter

 

Size:

 

​​

1

 

Byte 

Available

 

Settings

:

 

​​

 

0,

 

1. 

0

 

 

Disable

 

Report 

1

 

 

Enable

 

Report 

Default

 

Setting:

 

​​

1. 

2.

 

Meter

 

Report

 

Interval 

This

 

parameter

 

defines

 

interval

 

time

 

(in

 

seconds)

 

that

 

Meter

 

report

 

data

 

to

 

main 

controller. 
Function:

 

​​

Set

 

Report

 

Interval 

Parameter

 

Number:

 

​​

2. 

Parameter

 

Size:

 

​​

2

 

Byte 

Available

 

Settings

​:​

 

1

 

 

65535(s). 

Default

 

Setting:

 

​​

300(s) 

3.

 

Configure

 

maximum

 

over

load

 

current. 

This

 

parameter

 

defines

 

maximum

 

current

 

the

 

plug

 

can

 

provide

 

to

 

load

 

that

 

be 

connected

 

to

 

plug.

 

If

 

the

 

current

 

consumed

 

by

 

load

 

is

 

greater

 

than

 

maximum

 

current, 

the

 

plug

 

will

 

cut

 

off

 

power,

 

and

 

send 

NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED

 

​​

to

 

associated 

devices

 

in

 

lifeline.

 

Red

 

Led

 

will

 

blink

 

every

 

second

 

until

 

current

 

is

 

normal

 

(less

 

than 

Parameter

 

#3).

 

You

 

must

 

remove

 

the

 

loader

 

and

 

turn

 

on

 

the

 

Plug

 

(press

 

the

 

button 

once)

 

to

 

enable

 

current

 

monitor

 

and

 

clear

 

​​

NOTIFICATION

 

ALARM

This

 

parameter

 

value

 

must

 

be

 

greater

 

than

 

#4.

 

If

 

user

 

set

 

this

 

parameter

 

to

 

default

 

by 

Configure

 

CC,

 

the

 

parameter

 

#4

 

will

 

be

 

set

 

to

 

default

 

value. 

Function:

 

​​

Set

 

the

 

upper

 

current

 

threshold. 

Parameter

 

Number:

 

​​

3. 

Parameter

 

Size:

 

​​

1

 

Byte 

Available

 

Settings

​:​

 

1

 

 

16

 

(Ampere). 

Default

 

Setting:

 

​​

13(A). 

4.

 

Configure

 

maximum

 

Alarm

 

current. 

This

 

parameter

 

defines

 

maximum

 

current,

 

if

 

the

 

current

 

plug

 

provide

 

to

 

load

 

is

 

greater 

than

 

this

 

parameter,

 

the

 

plug

 

will

 

light

 

yellow

 

LED,

 

but

 

plug

 

cannot

 

cut

off

 

power. 

This

 

parameter

 

value

 

must

 

be

 

less

 

than

 

parameter

 

#3.

 

If

 

user

 

set

 

this

 

parameter

 

to 

default

 

by

 

Configure

 

CC,

 

the

 

parameter

 

#3

 

will

 

be

 

set

 

to

 

default

 

value. 

Function:

 

​​

Set

 

Alarm

 

upper

 

current

 

threshold. 

Parameter

 

Number:

 

​​

4. 

Parameter

 

Size:

 

​​

1

 

Byte 

Available

 

Settings

​:​

 

1

 

 

Parameter

 

#3

 

(Ampere). 

Default

 

Setting:

 

​​

12(A). 

5.

 

Led

 

Display

 

Enable 

This

 

parameter

 

defines

 

the

 

LED

 

indication

 

Function

 

ON/OFF.

 

This

 

parameter

 

can

 

be 

configured

 

with

 

0

 

or

 

1,

 

where

 

0

 

means

 

disable

 

LED

 

indication

 

Function

 

and

 

will

 

always 

be

 

turn

off,

 

and

 

1

 

means

 

enable

 

LED

 

Function. 

Function:

 

​​

LED

 

Enable/Disable 

Parameter

 

Number:

 

​​

5. 

Summary of Contents for STW-W3350WU

Page 1: ...nual Power plug Model number STW W3350WU Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Siterwell Technology HK Co LTD ...

Page 2: ...rnately every 300 milliseconds Please get familiar with the terms below before starting the operations This Plug has function that remembers the relay states the plug will turn on after power up next time if the plug is turn on before the power cut off Manufacture ID 0x0266 Product ID 0x1087 EU Technical Parameters ON OFF control Compatible with 300 series and 500 series Measuring voltage current ...

Page 3: ...controller or gateway operating manual 3 Press the button three times within 1 5 second the device will enter exclusion mode And the LED will flash on and off with yellow alternately five times within 2 seconds Note If device has not been added to Z wave network the device will enter adding mode automatically when it is powered on You should let the controller enter adding mode first before power ...

Page 4: ...rgy consumption measuring These measurement results are sent to Z Wave Controller or Z Wave Gateway Voltage The Supply Power Voltage For Plug Current The Current for the Electric Device Connect to Plug Consumption Power Power Consumed by an Electric Device in an Instant unit Watt W Energy Energy Consumed by an Electric Device in a Period Most commonly Measure in Kilowatt hours kWh One kilowatt hou...

Page 5: ...OWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline Red Led will blink every second until current is normal less than Parameter 3 You must remove the loader and turn on the Plug press the button once to enable current monitor and clear NOTIFICATION ALARM This parameter value must be greater than 4 If user set this parameter to default by Configure CC the parameter 4 will be set to...

Page 6: ...r defines the timer function Enable Disable This parameter can be configured with 0 or 1 where 0 means disable time switch function and 1 enable The period will be defined in parameter 9 If this parameter is Set to 1 and when turn the plug relay on the timer in plug start run with time period defined in parameter 9 and the plug will turn the relay off Function Time switch Configure Parameter Numbe...

Page 7: ...ting This configuration is not influenced to OCP monitor and energy accumulated Function Meter Enable Parameter Number 12 Parameter Size 1 Byte Available Settings 0 1 Default Setting 1 LED Color Indicator LED Color Led Display Status Description Pink Blink 5 Times 1s Interval Power on or Reset and Not Add in Z Wave Network Blink 5 Times 500ms Interval Send Node Info when Press Button tripled Blue ...

Page 8: ...CH_ALL V1 COMMAND_CLASS_BASIC V1 SPECIFICATIONS Power Supply AC110 230V 10 50 60Hz Rate Load Current 13A 110 230V 50 60Hz Continuous Load 16A 110 230V 50 60Hz Momentary Load Power Consumption 0 13W EU Standards Compliance Radio Protocol Z Wave Radio Frequency EU 868 4MHz US 908 4MHz Valid Range Up to 60m outdoors Up to 30m indoors Depending on terrain and building structure Operational Temperature...

Reviews: