3
7. The hose must be protected from contact with hot or
sharp surfaces both during use and while in storage.
The hose assembly should be visually inspected prior
to each use of the heater. If excessive abrasion or
wear is evident, or the hose is cut, it must be replaced
prior to operating the heater. The replacement hose
assembly may be obtained from the manufacturer.
8.
DO NOT
use any pressure regulator or hose assembly
other than those supplied with the appliance.
Replacement pressure regulator and hose assembly
must be those specified. Replacement parts maybe
obtained from the manufacturer or your local sales
representative.
9. Installation and use of this heater must conform with
local codes and AS/NZS 5601.
10. This heater is designed to operate with a standard 9Kg
propane cylinder with Approved Cylinder Connection.
11. The valve outlet must be maintained in good condition.
When the cylinder is not in use, be sure to cover it
with a dust cap. A leak test should be performed with
soapy water whenever connecting a new cylinder.
NEVER
use a match to test for leaks.
12. The propane cylinder must be turned off whenever the
heater is not in use. When the heater is to be stored
indoors, the propane cylinder and the heater must be
disconnected and the cylinder stored in accordance
with the Standard for Storage and Handling of
Liquefied Gases.
13. The appliance has been designed with several safety
features which include a tip over switch.
IMPORTANT
Storage of an appliance indoors with the cylinder
attached is only permitted if the size of the cylinder
complies with AS/NZS 1596; otherwise cylinders must
be stored outdoors in a well ventilated area.
The guards are fitted to this appliance to reduce the risk
of fire or injury from burns and no part of it should be
removed.
This appliance must be protected from exposure to rain.
Any modification to the heater not described in the
installation instructions may compromise the safety of this
appliance. Special concern is as follows:
(1)
DO NOT
bypass thermocouple safety burner;
(2)
DO NOT
operate heater without the guard;
Clothing or other flammable materials should not be hung
from the heater, or placed on or near the heater. The area
above the burner may be extremely hot. Direct contact with
these metal surfaces should be avoided in order to prevent
burns or clothing ignition.
Heater specifications can be found on the data label.
Screw the coupling nut of regulator into the cylinder valve
outlet.
QCC CYLINDER CONNECTION DEVICE
Screw the coupling nut of regulator into the cylinder valve outlet.
Q.C.C. CYLINDER CONNECTION DEVICE
Type of Gas
ULPG/LPG
Consumption
40 MJ/h
Operating Pressure
2.75 kPa
Injector Size
1.85 mm