19
Troubleshooting Guide
When a malfunction occurs, refer to the troubleshooting guide below. If the problem persists,
please contact your local distributor and report the problem by referring to the ERROR CODE.
Symbol Description
Error display and Solution
1
Description
Nothing on LCD screen and no alarm sound when POWER & STEAM
switches are on.
Cause &
Remedy
1) No power supply.
→ Check your electrical power source.
→ Check power plug connection.
2) Emergency Stop switch
is pressed.
→ Release the Emergency Stop switch.
3) Fuse is blown.
→ Replace the fuse.
2
ATTENTION REQUIRED
DISPLAY
DESCRIPTION
REFILL WATER TANK
icon is flashing in
red color and buzzer is beeping.
◆ Not enough water in the water tank.
Cause &
Remedy
1) Water shortage.
→ Refill water to the water tank.
2) Malfunction of the float
switch in the water tank.
→ Disconnect one wire from the float
switch of water tank and if the error
disappears, replace the float switch and
connect wires in position.
Alarm beeps
continuously
Alarm beeps once
Continuous pressure increases over
9 bar (130 psi)