background image

17 

 

Maintenance                                                                                 

Before to check product 

 

Must cool down the product. 

 

Must get rid of pressure in the product. 

 

Wear appropriate protective gear. 

  Unplug to shut down the power. 

  Caution of burn 

  Keep the below maintenance schedule. 

 

Maintenance Schedule 

 

Maintenance items 

Daily

Monthly 

Every 

3months 

Every 

6months

Drain boiler 

 

 

 

 

 

Drain Water / Fuel tank 

 

 

 

 

 

Replace filters 

 

 

 

 

 

 

Check probes / clean or replace if necessary 

 

 

 

 

 

Check electrodes and fuel nozzle and clean it
(Contact dealer) 

 

 

 

 

Descale boiler inside 
(Contact dealer) 

 

 

 

 

Clean Cylinder inside / remove soot 
(Contact dealer) 

 

 

 

 

※For your safety, the Safety Relief Valve must be replaced when a leak is present. If no 
leak occurs, the Safety Relief Valve must still be replaced every 3 years. 

OPTIMA XD

 

OPTIMA XE

 

 

 

Summary of Contents for OPTIMA X Series

Page 1: ......

Page 2: ...Fax 82 51 521 3305 Website http www sjecorp com E mail sales sjecorp com All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior permission of SJE Corporation Ltd Printed in Republic of Korea SJE20170101 ...

Page 3: ...Manufactured by SJE Corporation Ltd User s Manual Model OPTIMA X SERIES Ver G2 3 G2 7 Distributor s Contact Information ...

Page 4: ...uded Items and Accessories 9 Pre Start Procedure 10 Standard Operating Procedure 12 Adjust air flow For OPTIMA XD 15 Moisture Control 15 Emergency stop 16 Pause operation 16 Shutdown operation 16 Maintenance 17 Freeze Prevention 23 Fuse change 25 Troubleshooting Guide 26 Service Request 35 OPTIMA STEAMER Limited Warranty 35 ...

Page 5: ...d processing equipment removing weeds and more Product Specifications 1 OPTIMA XD Model OPTIMA XD Working Pressure 7 8 5 kgf Max 9 5 kgf 99 120 8 psi Max 135 1 psi Steam Vessel Temp 178 max 200 352 4 max 392 Preheating Time 2 3 min Voltage 100V 110 120V 220 240V 50 60Hz Customer configuration available Electrical Power 100V 110 120V 220 230V 450W 350W 300W Rated Flow Max 300 1200cc min 0 08 0 32gp...

Page 6: ... 415V 440V 460V 480V 600V 50 60Hz custom config available 3 phase 380V 415V 440V 460V 480V 600V 50 60Hz custom config available Rated Flow Max 300 1200 cc min 0 08 0 32 gpm Water Tank Capacity 72 ℓ 19 gal Net Weight 81 kgs 178 5 lbs 84 kgs 185 1 lbs 85 kgs 187 3 lbs 91 5 kgs 201 7 lbs Dimensions L x W x H 995 x 660 x 887 mm 39 x 26 x 35 inch Water consumption can be different depending on the use ...

Page 7: ... Front wheel 6 Lateral Side panel 7 Rotary caster 8 Grounding chain 9 Quick plug for feed water 10 Drain valve 11 Moisture control valve 12 Steam outlet valves 13 Electrical cable holder 14 Specification sticker 15 Handles 16 Control panel box 17 LCD Display 18 Pressure gauge 19 Fuel tank 20 Flue ...

Page 8: ...ndicator 5 Front wheel 6 Lateral Side panel 7 Rotary caster 8 Grounding chain 9 Quick plug for feed water 10 Drain valve 11 Moisture control valve 12 Steam outlet valves 13 Electrical cable holder 14 Specification sticker 15 Handles 16 Control panel box 17 LCD Display 18 Pressure gauge ...

Page 9: ...LES DO NOT direct air or discharge the steam jet at itself persons animals or live electricity Use and store the product on a level ground surface only DO NOT use the product if any part power cord safety device hose or spray gun are visually damaged or suspected of being damaged DO NOT use the product in rainy or snowy weather outdoors This product is not weather proof or water proof Never leave ...

Page 10: ...r in accordance with the electrical specifications Contact manufacturer or distributors for right extension cord Keep out of reach of children and pets This product is not intended for use by children or by persons with reduced physical sensory or mental capabilities or by person lacking experience with the product or knowledge of the product s use unless they have given supervision or instruction...

Page 11: ...on DO NOT use the product within a confined space DO NOT breathe in smoke from the exhaust flue to avoid smoke inhalation Use the product in well ventilated indoor area and install exhaust duct system if necessary See page 8 Ventilation set up Sample of Ventilation set up for OPTIMA XD Users about to use the OPTIMA XD indoors should carry out installation of exhaust duct system ...

Page 12: ...A71607 Silent Nozzle OPTIMA XD XE 18K 27K 70612 Couplings D 1 2 5 8 PTC OR A71619 Garden hose adapter 3 4 70066 L wrench 3 0mm OPTIMA XD 70069 L wrench 4 0mm OPTIMA XD XE 70007 T wrench 10mm 70008 T wrench 12mm 15 55002 T wrench 14mm 70004 Screwdriver 25 55001 Multi spanner 70175 Water probe sensor 3EA 70911 O ring D 22 70917 O ring D 17 71370 Water Filter 82 24006 Fuel filter with silicon OPTIMA ...

Page 13: ...utlet valves Ensure a tight connection using appropriate tools 2 Ensure that valves including drain valve steam outlet valves are fully closed 3 Ensure that tank drain plugs or water feeding tube are well connected See illustrations below OPTIMA XD OPTIMA XE 4 Fill the fuel tank For OPTIMA XD Open the black colored fuel tank cap on the right side and fill the tank Ensure the location of fuel tank ...

Page 14: ...trical sockets and plugs OPTIMA XD OPTIMA XE Single Phase 5K 3 Phase 12K 18K 27K Alert users to the presence of dangerous voltage inside the product that might cause bodily harm or electric shock For the use of OPTIMA XE make sure to connect the GROUND WIRE G to GROUND TERMINAL Never connect GROUND WIRE to NEUTRAL N TERMINAL Water Quality Matters Water quality can greatly affect the product s life...

Page 15: ...duct Never leave the product unattended while operating Surface of an exhaust flue or valves may be hot Take precautions while operating DO NOT apply any physical impact to the control panel box or leave any objects on it DO NOT press LCD Display with your hands or any objects LCD ICON DESCRIPTION WATER FUEL STEAM VESSEL WATER PUMP HEATING XD HEATING XE PRESSURE GAUGE STEAM READY TEMPERAURE AIR PU...

Page 16: ...ion after draining all the water out of the steam vessel completely 2 Main Screen Description Switch on the POWER and Initial boot up screen is displayed with the following information MAIN BOARD VERSION DISPLAY BOARD VERSION OPERATING TIME OPERATING STATUS MESSAGES 3 Main Screen Description Switch on STEAM Operating status messages and error signals are displayed Activate water pump to supply wat...

Page 17: ...er probe sensor in the steam vessel water pump stops When steam temperature reaches to 80 100 air purge valve is closed and AIR PURGE ON symbol is disappeared from the LCD Display 6 Main Screen Description When steam pressure reaches to 8 5 bar combustion stops and STEAM READY message is displayed Blower fan stops running and its symbol is disappeared in 30 seconds from the moment STEAM READY symb...

Page 18: ... adjustment damper clockwise Whitish Smoke from exhaust flue Move air adjustment damper counter clockwise DO NOT breathe in combustion gas from the exhaust flue Moisture Control Users can spray moisturized steam wet steam by opening the moisture control valve In the event of cleaning interior surfaces or water sensitive areas ensure that the moisture control valve is fully closed to minimize surfa...

Page 19: ...the gun trigger It prevents remaining of condensed water residue in the steam hoses afterwards and increases the life span of the steam hoses and guns Shutdown operation 1 Switch off the STEAM 2 After blower fan stops automatically applied to XD model switch off the POWER 3 Release steam from the steam vessel by pulling the gun trigger until the pressure drops down to 1 2 kg 28 4 psi 4 Close the s...

Page 20: ...onthly Every 3months Every 6months A Drain boiler B Drain Water Fuel tank C Replace filters D Check probes clean or replace if necessary E Check electrodes and fuel nozzle and clean it Contact dealer F Descale boiler inside Contact dealer G Clean Cylinder inside remove soot Contact dealer For your safety the Safety Relief Valve must be replaced when a leak is present If no leak occurs the Safety R...

Page 21: ... next use Wear appropriate protective gear for eyes and hands because steam is very hot Leave drain valve open until the next use B Drain Water Fuel tank Open drain plug under the tank or disconnect the tank connection hose Caution Slippery when wet OPTIMA XD Open drain plug under the tank OPTIMA XE Push the fitiing and pull out the hose ...

Page 22: ...ng left 4 Insert hose to filter and push it until it connects completely you can not pull out the hose by hand There is fuel filter for OPTIMA XD Please check it regularly and replace it if necessary How to replace fuel filter 1 Drain out all fuel from fuel tank by opening drain plug under the tank Refer P 18 2 Disconnect the fuel hose from fuel filter by pulling 3 Replace new fuel filter Check th...

Page 23: ... out the water tube See below image 3 Rotate the water filter counterclockwise to detach it 4 Install a new water filter in reverse order of disassembly 0 5 Open the Water filter shut off Valve Most Important Step Be careful with the filter installation direction See above images CAUTION You must keep the valve opened during machine operation If you damage the machine with this issue it will not b...

Page 24: ...s away from the fuel filter 3 Install a new fuel filter in reverse order of disassembly 4 Open the Fuel filter shut off valve Most Important Step Be careful with the filter installation direction See above image CAUTION You must keep the valve opened during machine operation If you damage the machine with this issue it will not be covered under warranty ...

Page 25: ...re 1 Unplug the power plug and then remove pressure completely by opening steam valve 2 Open the drain valve and drain out all water from boiler 3 Detach top cover and front cover Then detach the all wires from water probe sensors 4 Disconnect water probe sensors from steam vessel by 14mm long box wrench 5 Clean the water probe sensor by soft sand paper Replace it if necessary 6 Wind Teflon tape 6...

Page 26: ...e under 2 kg 28 4 psi and then drain out water from the steam vessel by opening a drain valve Leave the drain valve open until the next use Steam is extremely hot we are appropriate hand and eye protection Leave drain valve open until next use 2 Drain Water tank Open a drain plug or water tank connection tube under the water tank Caution Slippery when wet OPTIMA XD Open drain plug under the tank O...

Page 27: ...torage Keep Product in a warm place to prevent for being frozen Pipe line or parts can be ruptured if product is frozen badly Freeze can cause malfunction If product would be frozen do not operate it immediately Put the product in warm place in order to thaw After that check if there is any damage If the machine is visually damaged or performs abnormally immediately turn off the machine and contac...

Page 28: ...cap with a screw driver to take out 2 Replace into a new fuse 3 Push and turn clockwise the fuse cap with a screw driver to lock 2 TYPE B 1 Push and turn anticlockwise the fuse cap to take out 2 Replace into a new fuse 3 Push and turn clockwise the fuse cap to lock ...

Page 29: ...r plug connection 2 Emergency Stop switch is pressed Release the Emergency Stop switch 3 Fuse is blown Replace the fuse 2 ATTENTION REQUIRED ATTENTION REQUIRED Description REFILL WATER TANK icon is flashing in red color and buzzer is beeping Not enough water in the water tank Cause Remedy 1 Water shortage Refill water to the water tank 2 Malfunction of the float switch in the water tank Disconnect...

Page 30: ...rom the float switch of fuel tank and if the error disappears replace the float switch and connect wires in position 4 ERROR CODE DW01 ERROR CODE EW01 Description BOILER LEVEL ERROR icon is flashing in red color and buzzer is beeping Water level of the boiler may not enough Cause Remedy 1 Dirty water filter Check or replace the water filter 2 Malfunction of the water pump Check or replace the wate...

Page 31: ...Cause Remedy 1 Malfunction of the water probe sensors Clean or Replace the all water probe sensors of the boiler 6 ERROR CODE DW03 ERROR CODE EW03 Description BOILER LEVEL ERROR icon is flashing in red color and buzzer is beeping Pressure increase by water oversupply Cause Remedy 1 Malfunction of the water probe sensors Clean or Replace the all water probe sensors of the boiler ...

Page 32: ...ion of the water probe sensors Clean or Replace the all water probe sensors of the boiler 8 ERROR CODE DP21 ERROR CODE EP21 Description WATER PUMP OVERRUN icon is flashing in red color and buzzer is beeping The water pump runs overtime at initial operation XD 3 min XE 5 min Cause Remedy 1 Water filter blockage Check or Replace the water filter 2 Malfunction of the water pump Check or replace the w...

Page 33: ...ter 2 Malfunction of the water pump Check or replace the water pump 3 Malfunction of the water probe sensors Clean or Replace the all water probe sensors of the boiler 10 ERROR CODE DT31 ERROR CODE ET31 Description THERMISTOR ERROR icon is flashing in red color and buzzer is beeping Thermistor detects low temperature Under 0 32 Cause Remedy 1 Low temperature detection by freeze Defrost the machine...

Page 34: ...ction of the thermistor Replace the thermistor 12 ERROR CODE DT33 ERROR CODE ET33 Description THERMISTOR ERROR icon is flashing in red color and buzzer is beeping Thermistor detects high temperature Over 200 392 Cause Remedy 1 Malfunction of the pressure switch Replace the 8 5 bar pressure switch 2 Malfunction of the thermistor Replace the thermistor ...

Page 35: ...mp Check or Replace the fuel filter or fuel pump 3 Malfunction of the flame detector Replace the flame detector 4 Malfunction of the pressure switch Replace the 8 5 bar pressure switch 14 ERROR CODE DF42 DOES NOT APPLY Description NO FLAME DETECTED icon is flashing in red color and buzzer is beeping Abnormal detection of flame detector Cause Remedy 1 The flame sensor has been exposed by light from...

Page 36: ...hing in red color and buzzer is beeping PCB Relay malfunction Cause Remedy 1 Malfunction of the Control card Replace the Control card 16 REBOOT SYSTEM DOES NOT APPLY Description Showing REBOOT SYSTEM message and buzzer beeping Cause Remedy 1 24 hours continuous operation Turn off and on the Power Switch ...

Page 37: ...Damaged by freeze rupture Replace a broken part 3 Damaged piping line Fix or replace a broken part 18 Description Water supplying tube of water pump is hot or damaged Cause Remedy 1 Malfunction of the non return valve Replace the non return valves and damaged parts 19 Description Water tank is abnormally hot Cause Remedy 1 Malfunction of the air purge valve Clean or Replace the air purge valve 2 M...

Page 38: ...t consulting with an authorized technician f Damage or malfunctions resulting from natural calamity freezing theft accident vandalism abuse due to misapplication and or improper site conditions g Water damage h Electrical damage from including but not limited to improper use of extension cords failure to meet proper voltage requirements incorrect or insufficient amperage circuit i Insufficient uno...

Page 39: ...after discovery c Provide proof of purchase purchase date and serial number of the warranty item s d Make the unit available for inspection and repairs at dealer s place or service center If shipped transit costs should be prepaid For warranty service request please e mail tech sjecorp com or call 82 51 521 3200 SJE Corporation Ltd recommends that you read the Operating Instructions and in particu...

Page 40: ......