27
OPTIMA XD
OPTIMA XE
3
ATTENTION REQUIRED
DOES NOT APPLY
Description
REFILL FUEL TANK
icon is flashing in red color and
buzzer is beeping.
◆ Not enough fuel in the fuel tank.
Cause
&
Remedy
1) Fuel shortage.
→ Refill fuel to the fuel tank.
2) Malfunction of the float
switch in the water tank.
→ Disconnect one wire from the float
switch of fuel tank and if the error
disappears, replace the float switch and
connect wires in position.
4
ERROR CODE : DW01
ERROR CODE : EW01
Description
BOILER LEVEL ERROR
icon is flashing in red color
and buzzer is beeping.
◆ Water level of the boiler may not enough.
Cause
&
Remedy
1) Dirty water filter.
→ Check or replace the water filter.
2) Malfunction of the water
pump.
→ Check or replace the water pump.
3) Malfunction of the water
probe sensors.
→ Clean or Replace the all water probe
sensors of the boiler.