Preparation for Use
Input / Output Connections
Strobe Light
2 - 3
User Manual
remote sensor may not be powered
up.
The input jack (
pointing into socket) enables an
external signal to trigger the strobe. Inserting a plug
into the input jack will automatically put the strobe
into the External Input Mode. When the plug is
removed, the strobe will be put back into the Internal
Mode. The Internal Mode can be forced by pressing
the INPUT button. The polarity of the input pulse can
be set in the MENU options.
With no external input, the output jack (
pointing
away from socket) provides a TTL compatible pulse
from the strobe’s internal oscillator. If an external
input is applied, the output pulse is in sync with the
input pulse. This output pulse may be used to trigger
a second stroboscope synchronously to illuminate
larger areas. Many strobes can be “daisy chained”.
The output jack of one strobe is connected to the
input jack of the next strobe causing all the strobes to
flash together and be controlled by the first strobe in
the chain. The polarity of the output pulse can be set
in the
MENU
options.