Applications
Balancing and Phase Measurement
5 - 6
Strobe Light
User
Manual
proceed to the next point, and then repeat the
process.
¾
The trigger must stay depressed until
the Microlog is finished processing
the data.
If the Microlog does not respond to the phase
reference signal supplied to it by the strobe, it is
possible that the Trigger Setup in the vibration data
collector may be reversed. If so, change the setup
from “positive” trigger slope to “negative,” or vice
versa, and try again.
When the strobe is tuned in Internal mode, and then
switched to
LOCK
mode, the filter in the strobe tracks
slight changes in speed. If the speed changes too
much or too fast, the strobe loses LOCK / TRACK and
stops flashing. It will be necessary to switch back to
Internal mode and repeat the adjustments. Also, try
switching between the Narrow and Wide Bandwidth
LOCK to optimize results. Generally, the Wide
Bandwidth will give best tracking results, and the
Narrow Bandwidth will give better stabilization.
¾
When it is necessary to have
repeatable phase measurements,
you must record the transducer
locations used. Also, the transducer
mounting method should be the
recorded. Stud mounting or
magnetic base mounting is preferred
since data taken with hand-held
transducers may lead to significant
phase differences.