Non ROUTE
How to Collect Pre
-
set Non ROUTE Measurements
For
Accel
,
Accel Time
,
Velocity
, and
gE
pre-set measurement types, the following
standard settings are taken from the current selected ROUTE measurement:
Sensitivity
Coupling
Detection
Window
Accel
– Performs a “standard” type vibration
Accel
eration measurement.
Measurement parameters are set to:
Units
- Accel (Gs)
Display Format
– Spectrum
High-pass frequency
-
1.1 Hz
Fmax
-
10 kHz
Lines/Samples
-
800 Lines
Averages
– 4
Input Channel
–
CH1
Overlap
– 50%
Ext. Trigger Slope
– Positive
Trigger Level
– 2 V
Bin Zeroing
–
On
Type
- Spectral
Accel Time
–
Performs the same “standard” type vibration Acceleration measurement,
but collects time waveform data. Measurement parameters are set to:
Units
- Accel (Gs)
Display Format
– Time
High-pass frequency
-
1.1 Hz
Fmax
-
8 kHz
Lines/Samples
–
6400 Lines / 16384 Samples
Averages
–
4 (time sync.) If a trigger is defined for the active ROUTE point, if
no trigger is detected only 1 average is taken.
Input Channel
–
CH1
Overlap
– 50%
Ext. Trigger Slope
– Positive
Trigger Level
– 2 V
Bin Zeroing
–
On
Type
– Time
Velocity
– Performs a “standard” type acceleration to velocity vibration measurement.
Measurement parameters are set to:
Units
– A -> V
Display Format
– Spectrum
High-pass frequency
-
1.1 Hz
Fmax
-
1 kHz
Lines/Samples
-
400 Lines
Averages
– 4
Input Channel
–
CH1
Overlap
– 50%
A - 4
SKF Microlog - GX Series
User Manual