10. Technical data (cont.)
page 48
EN
10. Technical data (cont.)
Designation
Unit
Values
Oil + air outlet lubrication line
-
M8x1, counterbore for double tapered sleeve pipe union for pipe
4
Oil inlet connection
-
M10x1, counterbore for double tapered sleeve pipe union for pipe
6
Compressed air inlet connection
-
M10x1, counterbore for double tapered sleeve pipe union for pipe
6
Operating pressure
bar
3 to 10
Air consumption (for lubrication point line with internal diameter
of 2.3 mm, oil per ISO VG 32 to 100)
Nl/h
1000 to 1500
Pressure switch for oil (contained in compact unit)
Function
-
NO-contact
Switching voltage, max.
V AC/DC
42
Switched current, max.
A
2.5
Switching capacity, max.
VA
100
Switching pressure
bar
20
Level switch (contained in compact unit)
Function
-
NC contact (opens when oil level falls)
Switching voltage, max.
V AC
250
Switched current, max.
A
0.7
Switching capacity, max.
VA
50
Pressure switch for minimum air pressure
Switching pressure
bar
1 to 10; set: 3
Switching capacity
-
Ohm load: 6A at 24 VDC and 0.5A at 220 VAC
inductive load: 6A at 24 VDC and 3A at 220 VAC
Control unit
Type
IG54-20-S4-I
Rated voltage
V
110 - 120 or 220 - 240
Rated frequency
Hz
50 or 60
Contact rating, max.:
-
250 V, 5 A
Pump cycle time limit
s
60 (non-adjustable)
Interval time
min
1 - 99 (adjustable)
Pump delay time
s
5 (non-adjustable)