11
SKF TKTI 10
4.1 Direct access button 1
With Direct access button 1 you can access:
a. Alignment
b. Several measurement options, if enabled in the Measurement Option menu.
a. Alignment
(if visible on
: see Direct access button 2).
As the visible and thermal camera are not co-incident the visible and thermal image often
need to be aligned. This is usually required when inspecting objects at different distances.
It is possible to align the thermal and visible (digital) images only on “Live” mode.
Further adjustments can be done on the saved images with the software.
1. Press Direct access button 2 to locate the camera on/off
option and toggle the centre button to turn the camera
option on.
2. Press Direct acces button 1 to locate the alignment
option.
3. Alignment presets are accessible with centre toggle
button. You can also use the navigation buttons for final
adjustment.
Press left navigation arrow
fully aligned
Press right navigation arrow
Note
: Only the digital image is moving.
Figure 13. Examples of alignment