11
LUBRICATION
Bearings
The WC1105 chipper has four bearings. Figures 9 & 10 show the bearings on the input shaft
where the PTO shaft attaches. These bearings should be greased lightly every 8 hours of use.
Be sure to wipe all the dirt off of the fitting before greasing.
Figure 11
Figure 12
Figure 13
Figure 14
Figures 11 & 12 show the rotor shaft bearings. These should also be greased lightly every 8
hours. When greasing a sealed bearing, be careful that you do not overgrease or the grease will
push the rubber seal away and expose the bearing to dirt and moisture.
Shields have been removed to show detail. All shields must be on at all times during operation.
There are grease fitting for the chipper chute
adjustment. These should be greased as need-
ed if the chute begins to require extra force to
rotate.
Figure 15