Specifications

SKOPE Industries Limited reserve the right to alter specifications without notice.

Contact Addresses

Dimensions

Model:

PLC075

PLC125TI

PLC150TI

PLC200TI

Height:

430mm

430mm

430mm

430mm

Width:

442mm

614mm

680mm

852mm

Depth:

93mm (includes rear fixing bracket)

Weight:

3.7 kg

4.9 kg

5.4 kg

6.5 kg

Electrical

Wattage:

675-750 W

1125-1250 W

1350-1500 W

1800-2000 W

Supply:

230-240 Volts a.c. 50 Hz.

Wiring:

1.8m flexible cord and plug. This appliance 

MUST

 be Earthed.

Ingress Protection Rating: IPX4

New Zealand

SKOPE

 

INDUSTRIES LIMITED

PO Box 1091, Christchurch

New Zealand

Freephone: 0800 947 5673

Fax: (03) 983 3896

Email: enquiry@skope.co.nz

Website: www.skope.co.nz

Australia

SKOPE

 

AUSTRALIA PTY LTD

A.C.N. 000 384 270

PO Box 7543, Baulkham Hills B.C.

NSW 2153, Australia

Freephone: 1800 121 535

Freefax: 1800 121 533

Email: enquiry@skope.com.au

Website: www.skope.com.au

Summary of Contents for CONSORT PLC075TI

Page 1: ...PLC075TI PLC125TI PLC150TI PLC200TI SKOPE CONSORT Convection Panel Heaters Installation and Operating Instructions MAN0981 Rev 2 0 March 2010...

Page 2: ...es or place any object or material up against the unit as this may block entry or exhaust of airflow Do NOT probe any opening to remove fluff To ensure trouble free performance it is recommended that...

Page 3: ...alia and New Zealand AS NZS 3000 2000 Wiring Rules IMPORTANT The heater must not be located immediately below a socket outlet A suitable disconnection device acting in all active supplies is required...

Page 4: ...he rear panel 2 Fix wall bracket to wall using the four fixing screw holes provided see Figure 1 for dimensions 3 Locate heater onto both bottom lugs of the wall bracket 4 Hinge heater upwards and rep...

Page 5: ...both switches depressed will give full heat output Thermostat The heater is fitted with a built in thermostat to control the temperature level to which the room is heated The thermostat adjustment kn...

Page 6: ...nce of the timer adjacent to the time required outwards This will cause the heater to switch On at the selected time for 15 minutes operation Each additional segment pressed out will give a further 15...

Page 7: ...ries a Do Not Cover label to warn the user that if the appliance is covered there is a risk of overheating CAUTION In order to avoid a hazard due to inadvertent resetting of the thermal cutout this ap...

Page 8: ...4 kg 6 5 kg Electrical Wattage 675 750 W 1125 1250 W 1350 1500 W 1800 2000 W Supply 230 240 Volts a c 50 Hz Wiring 1 8m flexible cord and plug This appliance MUST be Earthed Ingress Protection Rating...

Reviews: