11
SKOPE OD460
Operation
User Manual
Electronic Controller
Introduction
The OD460 chiller is fitted with a Carel ir33 electronic controller which is
visible through a cut-out in the cabinet front panel.
The electronic controller switches the chiller between Day and Night modes
depending on the night blind position, and uses temperature probes to
control and display the chiller temperature, collect data, signal temperature
alarms and force a defrost cycle when required.
The electronic controller is pre-programmed and requires no initial setup or
additional programming. SKOPE does not recommend that the settings be
changed unless it is absolutely necessary.
Day and Night
Modes
The electronic controller will automatically switch the chiller between Day
and Night modes depending on the night blind position. When the blind is in
the open (up) position, the chiller runs in Day mode. When the blind is in the
closed (down) position, the chiller runs in Night mode.
During Day mode, the lights are ON and the chiller keeps product at required
(cool) temperature for serving, and the chiller temperature is displayed on
the controller display.
During Night mode,
nHt
is displayed on the controller display, the lights are
OFF and the chiller slightly elevates the product temperature to achieve
higher energy efficiency during store closing hours.
Note:
The chiller is suitable for storage of perishable products in either Day
or Night modes (all shelves maintain temperatures below 5°C).
CAUTION
The electronic controller must only be adjusted by an
authorised service agent.