SKOPE OD460

Maintenance

User Manual

Maintenance

To ensure the chiller continues to run efficiently and reliably, the following 
maintenance should be carried out:

To clean the condenser coil

Cleaning Cabinet

Keep the interior and exterior of the cabinet 

clean by regular wiping with a damp cloth.
The bottom shelf can be removed to assist 

with cleaning by undoing the two side fixing 

screws. Ensure the bottom shelf is refitted 

before reconnecting the chiller to the power 

supply.
Be careful not to

 

wash any liquid down into 

the refrigeration system, as this could lead 

to refrigeration failure.

Cleaning Condenser Coil

The condenser coil must be cleaned at least 

monthly with a soft brush to remove dust 

and fluff (see instructions below).

Regular Servicing

A thorough service clean must be 

completed by qualified service personnel 

every six months.

Time Frames

Time frames specified above are indicative 

only. More regular cleaning and servicing 

may be required depending on chiller 

placement and operating environment.

1. Remove the front panel and isolate the chiller from the power supply (see 

page 16).

2. Brush the condenser coil 

with a soft brush

3. Refit the front panel and reconnect to the power supply.

WARNING

Disconnect the chiller from the power supply before cleaning 

the condenser coil.

Condenser coil

Summary of Contents for OD460

Page 1: ...OD460 SKOPE Open Deck Chiller User Manual MAN11106 Rev 2 0 Nov 2018...

Page 2: ......

Page 3: ...7 Installing the Shelves 7 Optional Gravity Shelf System 8 2 Operation Automatic Start Up 9 Lights 9 Night Blind 9 Loading Product 10 Electronic Controller 11 Introduction 11 Day and Night Modes 11 Fa...

Page 4: ...that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to...

Page 5: ...pin plug which exits the rear of the cabinet at floor level Locate the power cord before the cabinet is moved into position so that it is not trapped behind the cabinet The cabinet must have its own d...

Page 6: ...ation exhaust air must NOT be allowed to run horizontally across the top of the cabinet as it may be pulled down into the cabinet interior 30mm rear spacer 60mm min 60mm min 200mm min Free standing in...

Page 7: ...tments can be made by separating the shelf bracket into two parts and re slotting together using the alternative slots see image below To fit the shelves Alternative height adjustable slots Position f...

Page 8: ...ze shelves To fit the gravity feed matting and shelf dividers 1 Match up the shelf dividers with the corresponding mats 2 Starting from the LH or RH side of the mat fit the LH or RH end divider into t...

Page 9: ...e closed position or Day mode with the lights ON when in the open position The night blind is located at the top of the cabinet opening and is not visible when in the open position To close the night...

Page 10: ...first time When loading the cabinet shelves with product Allow adequate air space around each item to ensure even cooling and efficient operation of the chiller Remove some product if the shelves are...

Page 11: ...The electronic controller will automatically switch the chiller between Day and Night modes depending on the night blind position When the blind is in the open up position the chiller runs in Day mod...

Page 12: ...ashes when activation of the compressor is temporarily delayed 6 Fan Indicator On when the fans are operational 7 Defrost Indicator On when a defrost cycle is activated Flashes when the activation of...

Page 13: ...button Continuous Cycle The continuous cycle can be used to pull down the temperature of product inside the cabinet quickly During a continuous cool down the compressor runs continuously for a set tim...

Page 14: ...hes 2 To adjust the setpoint press either the and keys to display the required setpoint value 3 Press the key again to memorise the new setpoint value If this is not done within 60 seconds changes wil...

Page 15: ...clear airpath at the top and front of the cabinet to extract hot air A minimum of 200mm clear space is required above and in front of the refrigeration unit 2 Ensure the cabinet is installed in a suit...

Page 16: ...rtment to turn off the electrics to the cabinet and refrigeration unit without unplugging the cabinet from the wall To isolate the electrics 1 Remove the front panel from the cabinet by undoing the fi...

Page 17: ...this could lead to refrigeration failure Cleaning Condenser Coil The condenser coil must be cleaned at least monthly with a soft brush to remove dust and fluff see instructions below Regular Servicing...

Page 18: ...lown cabinet fuse Arrange a service call Power consumption is higher than expected Refrigeration unit operating too hot Clean the condenser coil see page 17 Ensure the cabinet has good ventilation aro...

Page 19: ...A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au OD460 SKOPE Open Deck Chiller User...

Reviews: