background image

4

Installation

User Manual

SKOPE OD460

1

  Installation

Safety First

Always observe safety precautions when using any electrical appliance. 
Read these instructions carefully and retain them for future reference.

When the appliance is used by or near young children or infirm persons, 
close supervision is necessary, especially to ensure children do not play 
with it.

Do 

not

 use this appliance for other than its intended use.

Do 

not

 cover the grilles or block the entry or exhaust of airflow by 

placing objects up against the refrigeration unit.

Do 

not

 probe any opening.

Only use this appliance with the voltage specified on the cabinet rating 
label.

Ensure the chiller has adequate ventilation as this is essential to 
economical, high performance.

Be careful not to touch moving parts and hot surfaces.

For your own safety and that of others, ensure that all electrical work is 
done by authorised personnel.

If the power supply flexible cord becomes damaged, it must be replaced 
by an authorised service agent or similarly qualified person in order to 
avoid a hazard.

Ensure all necessary safety precautions are observed during installation 
or removal of the refrigeration unit.

The chiller is not designed to be stable while in motion. Use extreme 
caution when moving or transporting it.

Do not store explosive substances such as aerosol cans with a 

flammable propellant in this appliance.

Please contact SKOPE Customer Services for advice regarding 
disposal of this appliance.

WARNING

Disconnect the cabinet from the mains power supply before 

attempting any cleaning or maintenance.

CAUTION

Never

 overload the power supply, which could damage the 

chiller and product. See the rating label inside the cabinet for 

the safe power supply and current draw.

CAUTION

Do 

NOT 

allow liquids or any other materials to drain into the 

bottom of the cabinet, as this could lead to refrigeration 

system failure.

 

Summary of Contents for OD460

Page 1: ...OD460 SKOPE Open Deck Chiller User Manual MAN11106 Rev 2 0 Nov 2018...

Page 2: ......

Page 3: ...7 Installing the Shelves 7 Optional Gravity Shelf System 8 2 Operation Automatic Start Up 9 Lights 9 Night Blind 9 Loading Product 10 Electronic Controller 11 Introduction 11 Day and Night Modes 11 Fa...

Page 4: ...that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to...

Page 5: ...pin plug which exits the rear of the cabinet at floor level Locate the power cord before the cabinet is moved into position so that it is not trapped behind the cabinet The cabinet must have its own d...

Page 6: ...ation exhaust air must NOT be allowed to run horizontally across the top of the cabinet as it may be pulled down into the cabinet interior 30mm rear spacer 60mm min 60mm min 200mm min Free standing in...

Page 7: ...tments can be made by separating the shelf bracket into two parts and re slotting together using the alternative slots see image below To fit the shelves Alternative height adjustable slots Position f...

Page 8: ...ze shelves To fit the gravity feed matting and shelf dividers 1 Match up the shelf dividers with the corresponding mats 2 Starting from the LH or RH side of the mat fit the LH or RH end divider into t...

Page 9: ...e closed position or Day mode with the lights ON when in the open position The night blind is located at the top of the cabinet opening and is not visible when in the open position To close the night...

Page 10: ...first time When loading the cabinet shelves with product Allow adequate air space around each item to ensure even cooling and efficient operation of the chiller Remove some product if the shelves are...

Page 11: ...The electronic controller will automatically switch the chiller between Day and Night modes depending on the night blind position When the blind is in the open up position the chiller runs in Day mod...

Page 12: ...ashes when activation of the compressor is temporarily delayed 6 Fan Indicator On when the fans are operational 7 Defrost Indicator On when a defrost cycle is activated Flashes when the activation of...

Page 13: ...button Continuous Cycle The continuous cycle can be used to pull down the temperature of product inside the cabinet quickly During a continuous cool down the compressor runs continuously for a set tim...

Page 14: ...hes 2 To adjust the setpoint press either the and keys to display the required setpoint value 3 Press the key again to memorise the new setpoint value If this is not done within 60 seconds changes wil...

Page 15: ...clear airpath at the top and front of the cabinet to extract hot air A minimum of 200mm clear space is required above and in front of the refrigeration unit 2 Ensure the cabinet is installed in a suit...

Page 16: ...rtment to turn off the electrics to the cabinet and refrigeration unit without unplugging the cabinet from the wall To isolate the electrics 1 Remove the front panel from the cabinet by undoing the fi...

Page 17: ...this could lead to refrigeration failure Cleaning Condenser Coil The condenser coil must be cleaned at least monthly with a soft brush to remove dust and fluff see instructions below Regular Servicing...

Page 18: ...lown cabinet fuse Arrange a service call Power consumption is higher than expected Refrigeration unit operating too hot Clean the condenser coil see page 17 Ensure the cabinet has good ventilation aro...

Page 19: ...A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au OD460 SKOPE Open Deck Chiller User...

Reviews: