9
SKOPE OD460
Operation
User Manual
2
Operation
Automatic Start-Up
After the cabinet has been positioned in a suitable place, plug it in and check
the following activity.
Lights
The chiller is fitted with interior LED lights. The lights turn off and on
automatically when the chiller is switched between Night and Day mode (via
night blind or electronic controller button, see “Day and Night Modes” on
page 11). The lights can also be switched on and off manually without
changing the chiller between night and day mode by pressing the light
button on the electronic controller faceplate (see “Faceplate” on page 12).
Lighting components must not be tampered with in any way. If a unit is
suspected of being faulty, a service call should be arranged so that a
replacement component can be fitted.
Night Blind
The chiller is fitted with a manual night blind which should be pulled down
into the closed position during store closing hours to save power. The night
blind has a switch which automatically tells the electronic controller to run
the chiller in Night mode (with the lights OFF) when the blind is in the closed
position or Day mode (with the lights ON) when in the open position.
The night blind is located at the top of the cabinet opening and is not visible
when in the open position.
To close the night blind, use the handle to pull the blind down and hook it
under the night blind retaining brackets at the bottom of the chiller opening.
To open, use the handle to release the blind from the retaining brackets and
control the blind as it opens.
Item
Activity
Electronic
controller
An electronic controller runs the chiller and is visible behind
the front panel. The display panel first flashes start-up
messages before stabilising on the cabinet temperature.
Lighting
If the night blind is up, the lights that illuminate the cabinet
interior will come on a few seconds after the chiller is turned
on.
The lights are off when the night blind is down.
Refrigeration unit
The refrigeration unit evaporator and condenser fans should
all operate continuously from the time the cabinet is plugged
in. This may be verified by checking for air movement inside
the cabinet. The internal cabinet air will continue to circulate at
all times.
The compressor will start after approximately one minute, will
switch off when the cabinet internal temperature reaches
approxi1.5°C and on again at approxi4°C.