6
Installation
User Manual
SKOPE Pegasus Horizontal Series
Locating the Cabinet
Location
When positioning the cabinet, avoid direct sunlight and warm draughts etc.
The cabinet must NOT be situated where it is affected by warm or hot air
from adjacent equipment, as this will compromise the airflow and
performance of the chiller.
The cabinet must be positioned on a level surface for the doors to shut and
seal correctly, and to prevent the condensate tray from overflowing.
Adequate allowance should be made for door opening.
Always ensure that the top of the cabinet is shielded from impact and
moisture, with either a SKOPE provided bench top, or with a custom or
existing bench top.
Prep and Pizza chillers have pan openings with lids on the top of the cabinet.
Maximum air movement around the opening area of the cabinet must not
exceed 0.3 m/s. Excessive air movement will cause failure of the air curtain
above the pans and excessive temperature rise.
When installing the cabinet
Avoid direct sunlight and warm draughts etc.
Allow adequate space for the door/s and/or drawer/s to open fully.
Ensure the cabinet is positioned on a level surface so the door/s shut
and seal correctly and to prevent the condensate tray from overflowing.
Air movement above Prep and Pizza chillers must not exceed 0.3 m/s.
Ventilation
For efficient operation of the chiller, it is essential that adequate ventilation
be provided around the front of the refrigeration unit. Normal operating
conditions should not exceed the operating temperature range (see page 4).
It is critical that the hot refrigeration exhaust air is not restricted and that it
can easily flow out and away from the front of the cabinet. Never store
cardboard cartons or other items in front of the refrigeration unit. The
ventilation slots on the unit front cover must be kept clear at all times.
Power Supply
The chiller is supplied with a flexible power cord and plug, which for transit
purposes is located inside a compartment in the rear of the cabinet (see
image below).
Before final positioning of the chiller, pull the power cord out from the rear
compartment and connect to the power supply. For convenience, any
surplus cord length may be left inside the cabinet compartment.
WARNING:
Do
NOT
overload the power supply. See the rating label inside
the cabinet for power supply and current draw.
Power cord