12
Installation
User Manual
SKOPE Pegasus Horizontal Series
Electrical
The cabinet is supplied with a 10A flexible power cord and 3-pin plug. The
cabinet lighting and centre pillar heater elements are protected by a 3A fuse,
located in the unit junction box.
Once the chiller has been installed it can be disconnected from the mains
power supply by turning off the cabinet isolation switch and unplugging the
refrigeration unit supply isolation flexible cord - located inside the
refrigeration unit compartment (see diagram below).
Electronic
Controller
When the cabinet is connected to the power supply, the electronic controller
will display the current cabinet temperature. On the controller display, the
symbol will indicate the compressor output signal has been initiated and the
symbol will indicate the evaporator fan is on.
Refrigeration
Pipes and
Solenoid
A 1/4” liquid line and a 3/8” suction line are provided to attach pipes to. The
suction line must be insulated.
The electronic controller supplied with the cabinet can switch a solenoid. No
solenoid is supplied with the standard remote unit. If a solenoid is fitted and
controlled by the electronic controller, the solenoid will need to be connected
to the connector block inside the unit junction box.
Installation
Diagrams
Refer to the diagram below (Pegasus Horizontal 1-1) and over the page
(Pegasus Horizontal 2-1) for component locations and unit access points.
Pegasus Horizontal 1-1 installation diagram
19mm
drain tube
Mains
isolation box
Service ports (bottom
of refrigeration unit
compartment)
40
147
131
159
114
Side view
Front view
Bottom view
100
Cabinet
front
Cabinet
rear
Refrig. pipes
Service ports
(back of
cabinet)
50
50
Door
15