35
SK650-2
SKOPE Gen2: Single Door Chiller
Unit junction box
All electrical connections for the refrigeration unit are contained
inside the unit junction box, mounted on the front of the refrigeration
unit. To access the fan motor connections or to replace the fuse,
remove the unit junction box cover. To access the unit junction box:
1. Disconnect the cabinet from the mains power supply.
2. Undo the top and bottom screws from the unit junction box and
remove the cover, leaving the cover Earth wire still attached.
3. All electrical connections can now be accessed.
4. Ensure the unit junction box cover is replaced after servicing.
SERVICE INSTRUCTIONS
4
Figure 22: Unit Junction Box (with cover removed)
Fan Motor Flexes
Mains Flex
Cover Earth Wire
Fan Motor Capacitor
Junction Box Base
3 Amp Fuse
ENSTO 3-Way
Panel Adaptor