background image

10

Servicing

User Manual

SKOPE TME Series

Sign Light

New Zealand models only. The sign unit is lit by one T8 LED tube which can 
be replaced by removing the front sign panel. See the sign light 
specifications for each model in the table below.

Sign light specifications

To replace the sign light

4. Rotate the LED tube until 

the pins on the ends of the 
tube align with the slots, 
then slide it out.

5. Fit a new LED tube. 

Ensure the LED tube is 
fitted with the power end 
at the top (usually marked 
‘POWER’ or similar). 

6. Refit the pillar cover by  squeezing and snapping the pillar into place on the 

back of the cover as you work down the length of the light.

7. Fix the pillar in place with the fixing screw at the bottom of the pillar.

Model

Configuration LED Tube Specification

SKOPE Part No.

TME475

1 × sign light

5W, 360mm, T8 LED tube

ELL10435

TME650

1 × sign light

11W, 600mm, T8 LED tube

ELL10741

TME1000 1 × sign light

12W, 900mm, T8 LED tube

ELL10742

TME1500 1 × sign light

24W, 1500mm, T8 LED tube 

ELL10743

1. Disconnect the chiller from the power supply. 

2. Start at one of the top corners of the 

sign unit and pull the sign panel out 
from under the sign top cover.

3. Work along the length of the sign unit, pulling the sign panel out as you go.

4. Carefully remove the sign panel from the sign unit.

5. The tube can now be accessed for replacement. Rotate the failed tube until 

the pins on the end of the tube align with the slots, then slide it out.

6. Fit the new tube and rotate until it clicks into position.

7. Refit the sign panel. When refitting 

the sign panel, ensure both sign 
panel end strips fit neatly into the top 
and bottom corner notches.

Sign Top Cover

Corner
Notch

Sign Top Cover

Corner Notch

Sign Panel 
End Strip

Sign Panel

Summary of Contents for TME Series

Page 1: ...TME Series SKOPE Vertical Chiller User Manual MAN10259 Rev 4 0 Jul 2014 TME1000...

Page 2: ...535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty th...

Page 3: ...g the chiller 5 Power Cord 5 Chiller Location 5 Ventilation 5 Stabiliser Feet 5 Fitting the Illuminated Sign 6 Fitting the Shelves 6 2 Operation Start Up 7 Loading Product 7 3 Servicing Cleaning 8 Cab...

Page 4: ...o touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must b...

Page 5: ...ture for the chiller is 40 C Ventilation For effecient operation of the chiller it is essential that adequate ventilation be provided above the refrigeration unit Ensure there is always at least a 200...

Page 6: ...ventilated sign sides in position Slide the panels forward flush with the edges of the chiller and tighten the screws 2 Clip the sign back panel into retaining slots on the rear of the sign sides and...

Page 7: ...interior and where applicable the lit sign will come on when the chiller is turned on Thermostat The thermostat is pre set to give an internal air temperature of between 2 C and 4 C and under normal...

Page 8: ...soft brush or vacuum cleaner to remove any dust or blockage from the coil fins A more thorough cleaning is recommended every six months by qualified service personnel To clean the condenser coil WARNI...

Page 9: ...1500mm T8 twin LED tube ELL10603 1 Disconnect the chiller from the power supply 2 Remove the diffuser by squeezing it until it is released from the housing and then push the diffuser out of the way 3...

Page 10: ...pecification SKOPE Part No TME475 1 sign light 5W 360mm T8 LED tube ELL10435 TME650 1 sign light 11W 600mm T8 LED tube ELL10741 TME1000 1 sign light 12W 900mm T8 LED tube ELL10742 TME1500 1 sign light...

Page 11: ...t Clean the condenser coil see page 8 Ensure the chiller has good ventilation around the refrigeration unit see page 5 Ensure the chiller is in a cool spot chiller doors are opened excessively Ensure...

Page 12: ...mark to the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on th...

Reviews: