7
SKOPE TME Series
Operation
User Manual
2
Operation
Start-Up
After the chiller has been positioned in a suitable place, plug it in and check
the following activity.
Note:
After moving the chiller, allow the chiller to stand for at least 30
minutes before connecting to the power supply.
Loading Product
The chiller should be left running for 30 minutes before loading with product.
When loading the chiller shelves with product:
Allow adequate air space around each item to ensure even cooling and
efficient operation of the chiller.
Do not exceed a maximum load of 20kg per shelf.
Remove some product if the shelves are flexing.
Do not let anything overhang the shelves because this might stop the
doors from shutting or even break something.
Item
Activity
Lighting
The lights that illuminate the chiller interior, and where
applicable the lit sign, will come on when the chiller is
turned on.
Thermostat
The thermostat is pre-set to give an internal air
temperature of between 2°C and 4°C, and under normal
circumstances should not require adjustment. If you do
need to adjust the temperature, turn the thermostat shaft
protruding from the control box mounted on top of the
refrigeration unit. To make the temperature colder; turn the
thermostat clockwise. To make the temperature warmer;
turn the thermostat anti-clockwise.
Compressor,
Condenser and
Evaporator
Fans
The compressor, and evaporator and condenser fans
should all operate continuously from the time the chiller is
plugged in. This may be verified by listening for compressor
switch on and checking for air movement inside the chiller.
The compressor and condenser fan should switch off
when the chiller internal temperature reaches
approximately 2°C. and on again at approximately 4°C.
The internal chiller air will continue to circulate at all times.