12
Technical User Guide
DA 74BC Winch Motor
5
Maintenance Guide
DA 74BC does not require any special maintenance, however, we recommend that the system be serviced once
a year.
5.1
Cleaning
Clean the product with water and a brush without using:
high-pressure cleaner
solvents
corrosive/caustic agents
Figure 13: Cleaning
5.1.1
Annual Inspection
1)
Open the cabinet cover to check the inside functions; check also that no fluid can penetrate into the
cabinet as this may damage gears and other components. Pay attention to the shaft sealing and the
sealing of cable lead-throughs.
2)
Activate the manual release and check that the swivel shutter moves unobstructedly in its entire
working range.
5.2
Dismantling for Recycling/Disposal
SKOV A/S' products which are suited for recycling are marked with a pictogram showing
a refuse bin that is crossed over. See picture.
Customers can dispose of SKOV A/S products at local collecting points/recycling stations according to local
directions. The recycling station will then send the products to an approved plant for recycling and reuse.
5.2.1
LED Indication
OK
= slow flashing (1 flash/sec.)
Calibration = constantly on
Fault
= fast flashing (10 flashes/sec.)
Figure 14: LED