18
Technical User Guide
ECT/DCT 632-6 Fans
INSTALLATION GUIDE
3
Electric Connection
The installation, service and troubleshooting in connection with electrical equipment must be
carried out by specialists in accordance with applicable national rules - in Europe in accordance
with EN 60204-1 and other applicable EU rules.
The installation of a supply isolator is required for each motor and power supply, so
maintenance of electrical equipment can be carried out in a dead environment. Supply isolator is
not supplied by SKOV A/S.
3.1
Cabling
3.2 Colour Code
Colour code on the wires in appliance with the IEC 60757 standard: Alphabetic codes for identification of
colours used on drawings, diagrams, marking, etc.
Bogstavkode
Farve
BK
Black
BN
Brown
RD
Red
OG
Orange
YE
Yellow
GN
Green
BU
Blue (incl. light blue)
VT
Violet (purple red)
GY
Grey (slate)
WH
White
PK
Pink
GD
Gold
TQ
Turquoise
SR
Silver
GNYE
Green-and-yellow
Drill a hole for the cable and pull it along a leg to the same side as
the winch motor.