DOL 635 • DOL 639
User Manual
29
If the controller has an external button for activating pause and start, the contents
of the menu is synchronized after pressing the button. See section
.
Feed program
Setting for when and how many times feeding is necessary. See also the
section.
Diplays if the individual feedings have been carried out.
Volume dispenser
Dispenser 1 state
Display of volume dispenser’s current status:
•
Closed
. The system can fill the feed dispenser.
•
Opening
. Feed is emptied. 20 sec.
•
Open
: 2 sec.
•
Closing
: 20 sec.
•
Waiting for feed line
: Emptying the volume dispenser is blocked because it is
being filled. The emptying will resume again after successful feeding.
•
Manual
: The actual status is unknown during manual operation. Then return to
Closing
.
Dispenser 1 program
Setting for when and how many times the dispensers should supply feed.
If a feed line is parked, the controller will skip a programmed time.
If the dispensers are being filled, the emptying is postponed until filling has com-
pleted.
Empty dispenser
Activating a manual emptying of dispenser.
The system automatically closed the dispensers again.
Feed mixture
Feed mixture
Setting for the mixing ratio between the various types of feed.
The controller can control a dry feeding system via an automatic feeding program and control feed mixing as
well as manual feeding.
1. Silo auger
2. Feed weigher
3. Feed separation shutter Winch
motor
5. Feed stop sensor
6. Volume dispenser
7. Wire/chain system
Figure 2: Principle sketch of dry feeding system with two feed lines.
The two feed lines start at the same time but stop based on the input from the feed stop sensor of the feed line.