SKS-Kinkel Elektronik GmbH
EN
300090 Video compact power supply
Support-Hotline: +49 (0) 2661-98088-112
- 12 -
Version: 1.0
E-Mail: support@sks-kinkel.de
Document art. no. 97009500
5
DIP- switch
DIP- switch position
Function /
meaning
For the described functions the black highlighted DIP switches are respectively important. Grey DIP-switches have no
relevance for the respective function. Therefore, a combination of functions is also possible.
Normal operation
Ope
ra
ti
ng
m
ode
Power detection camera 1.
This option is necessary for older devices. The SKS BUS
(a+ / b-) is not required in this operation mode.
BUS commands only.
Use this mode if you use indoor stations with an on-screen menu
(e.g. DS2010) or for an entirely new installation.
Camera 1 continuously powered.
If the video image of the camera is, for instance, used
for a surveillance system, the camera has to be permanently active. This option is only
available if there is only one camera in the system. Is the camera continuously powered
the voltage at +22/GND will be 21V
Line expansion mode
. The video power supply 756 was previously required for the line
extension. Now the video compact power supply may be switched to this function. The
manual picture retrieval function will be deactivated for all indoor stations. For video
indoor stations of the DS2010 series this DIP switch cannot be set to ON.
W
it
h
3
0
0
0
2
0
(4814
)
Compatibility mode for indoor stations before 2010.
By lowering, the output voltage
indoor stations get a reset command. The voltage decreases to 0V and subsequently
increases to 28V. The reduction must be activated, if indoor stations of type 4505VB or il
vetro video are used in the installation. If the DIP-switch was pulled to the ON position,
the reduction is deactivated
Indo
or
s
ta
ti
ons
bef
ore
2
0
1
0
6
Technical data
Primary side
Input rated voltage
207 - 253VAC / 50Hz
Secondary side
Output rated voltage K1
– K4
0 - 28 VDC (+5/-10%)
Output rated current K1
– K4
max. 0,3 A
Output rated v22 / GND
0 - 28 VDC (+5/-10%)
Output rated c22 / GND
max. 0,7 A
Output rated v12 / GND
12 VDC (+5/-10%)
Output rated c12 / GND
max. 0,48 A
EMC-standard, safety standard
EMV 2014/30/EU: EN55022 and EN55024, EG
2014/35/EU, EN60950-1