300091 Floor compact power supply 

 

 

 

 

 

 

 

Support-Hotline: +49 (0) 2661-98088-112 

- 14 - 

Version: 1.3 

E-Mail: support@sks-kinkel.de 

 

Document art. no. 97009603 

 

1.2 

Warning 

 
Penetration  of  fluids  or  electrically  conductive  small  parts  can  cause  a  short  circuit,  fire  or  electric  shock.  The 
device must not be brought into contact with water or other liquids. 

Avoid the entry of electrically conductive small parts through the vents. 

The device generates heat in nominal operation. Provide a adequate ventilation. 

Do not cover the ventilation slots on the device.

 

 
 

Terminal designation 

 

Terminal 

Designation 

aEL+ / bEL- 

Output a+ / b- floorline 

LED+ / LED- 

Output door opener 

TÖ1 / TÖ2 

Output door opener 

aHL+ / aHL- 

Output a+ / b- mainline 

a / b / GND 

RS485 connector  

RJ11 

compact interface 

L / N / PE 

Supply voltage 

 
 

Description 

 
In the simplest scenario the SKS bus installation consists of a single line. This is the so-called main line. Only one 
call  may  be  conducted  at  a  time, even  if  there  are  several  door  stations.  The  floor  compact  power  supply  300091 
provides the opportunity  to build  on the floor lines. The floor line consists of at  least  one door station for that floor 
and the intercom units that belong to it.  
The floor compact power supply  300091 makes it possible to call direct from the floor  door station in the floor  line 
and at the same time direct a call on the main line to an indoor station that is not located in the floor line. 
The floor compact power supply is used whenever there are many door stations on every floor that are connected to 
the  main  door  station.  If  a  call  is  to  be  directed  from  the  main  door  station  to  a  call  station  on  the  floor  line  while 
another call is already being answered on another floor door station, there will be an acoustic busy signal. 
 
The  floor  compact  power  supply  is  used  whenever  there  are  audio  floor  door  stations  and  audio  indoor  stations 
being  used  with  audio  communication  to  the  main  door  stations.  In  connection  with  the  extended  video  compact 
power  supply  300092  it  is  possible  to  operate  video  floor  door  stations  and  video  indoor  stations  in  the  floor  line. 
There is also the possibility connect up to 30 nameplate illuminations as well as the door opener.  
Image  retrieval  from  floor  indoor  station  to  the  main  door  station  is  not  possible  whereas  image  retrieval  from  the 
floor call station to the floor door station is possible. 
The floor compact power supply is protected against overload and short circuiting. 
 

 

Summary of Contents for 300091

Page 1: ...tallationsanleitung Installation instructions SKS Kinkel Elektronik GmbH Version 1 3 Support Hotline 49 0 2661 98088 112 E Mail support sks kinkel de Dokument Art Nr 97009603 300091 Etagen Kompaktnetzteil ...

Page 2: ...aßnahmen Das Gerät muss so an die Versorgung angeschlossen werden dass der Benutzer keinen direkten Zugang zum Bereich der Netzanschlussklemme hat Außerhalb des Gerätes muss eine leicht zugängliche Trennvorrichtung vorhanden sein Das Gerät entspricht der Überspannungskategorie II Außerhalb des Gerätes ist eine Überstrom Schutzeinrichtung vorzuschalten Das Gerät muss über die Klemme PE an das Schut...

Page 3: ...espräch auf der Hauptlinie zu einer Innensprechstelle die sich nicht in der Etagenlinie befindet zu führen Das Etagen Kompaktnetzteil wird überall dort eingesetzt wo es viele Etagentürstationen zu den Haupttürstationen gibt Soll ein Gespräch von der Haupttürstation zu einer Sprechstelle in der Etagenlinie geführt werden während an einer Etagentürstation bereits gesprochen wird ertönt aus der Türst...

Page 4: ...tagen Kompaktnetzteil hat den Programmiermodus nach Ablauf der Programmierzeit deaktiviert Stellen Sie DIP 2 und 3 wieder auf OFF LED an Auf ON Position Das Etagen Kompaktnetzteil befindet sich im Programmiermodus 4 3 Störung LED Das Etagen Kompaktnetzteil 300091 generiert abhängig von einem aufgetretenen Fehler einen Fehlercode Dieser Fehlercode wird durch die Störung LED angezeigt Bei einem Fehl...

Page 5: ...N gestellt wird nur eine Englische Besetzt Ansage wiedergegeben Wird der DIP Schalter 4 auf OFF gestellt wird eine Deutsche und Englische Besetzt Ansage wiedergegeben 6 Programmieren von Etagensprechstellen Nachdem Sie die DIP Schalter Einstellungen am Etagen Kompaktnetzteil vorgenommen haben beginnen Sie mit der Programmierung der Rufadressen Wenn das Etagen Kompaktnetzteil im Programmiermodus is...

Page 6: ...e in die Etagenlinie gerufen werden Das Löschen erfolgt wie in der unten dargestellten Tabelle Arbeitsschritt Beschreibung 1 Stellen Sie den DIP Schalter 2 auf ON die Gespräch HL Prog LED leuchtet 2 Betätigen Sie die Licht Taste auf der zu löschenden Etagensprechstelle 3 Bei jeder erfolgreich gelöschten Etagensprechstelle geht die Gespräch HL Prog LED des Etagen Kompaktnetzteils kurz aus und die E...

Page 7: ...sgangsnennspannung aEL bEL 24VDC 20 Ausgangsnennstrom aEL bEL max 1A EMV Norm Sicherheit Norm EMV 2014 30 EU EN55032 und EN55024 EG 2014 35 EU EN60950 1 Allgemeines Temperatur 5 C bis 45 C Feuchtigkeit 20 bis 90 nicht kondensierend Gehäuse Kunststoff Hutschienengehäuse Abmessungen Breite x Höhe x Tiefe 105 x 90 x 71 mm 6TE Schutzart IP20 Schutzmaßnahmen Überspannungs und Überlastschutz Strombegren...

Page 8: ...SKS Kinkel Elektronik GmbH DE 300091 Etagen Kompaktnetzteil Support Hotline 49 0 2661 98088 112 8 Version 1 3 E Mail support sks kinkel de Dokument Art Nr 97009603 10 Strukturplan 2 Draht Audio ...

Page 9: ...SKS Kinkel Elektronik GmbH DE 300091 Etagen Kompaktnetzteil Support Hotline 49 0 2661 98088 112 9 Version 1 3 E Mail support sks kinkel de Dokument Art Nr 97009603 11 Verdrahtungsplan 2 Draht Audio ...

Page 10: ...SKS Kinkel Elektronik GmbH DE 300091 Etagen Kompaktnetzteil Support Hotline 49 0 2661 98088 112 10 Version 1 3 E Mail support sks kinkel de Dokument Art Nr 97009603 12 Strukturplan 6 Draht Video ...

Page 11: ...SKS Kinkel Elektronik GmbH DE 300091 Etagen Kompaktnetzteil Support Hotline 49 0 2661 98088 112 11 Version 1 3 E Mail support sks kinkel de Dokument Art Nr 97009603 13 Verdrahtungsplan 6 Draht Video ...

Page 12: ... 2012 19 EU WEEE und 2011 65 EU RoHS EU REACH Verordnung und Gesetz zu Durchführung der Verordnung EG Nr 1907 2006 Haftungsausschluss Wir haben den Inhalt der Druckschrift auf Übereinstimmung mit der beschriebenen Hard und Software geprüft Es können dennoch Abweichungen nicht ausgeschlossen werden so dass wir für die vollständige Übereinstimmung keine Gewähr übernehmen Die Angaben dieser Druckschr...

Page 13: ...work and all electrical connections must comply with the national provisions for the country in question and must be performed by appropriately trained personnel DIN VDE 0100 must be observed and complied with in devices with a 230V connection 1 1 Installation instructions and protection The unit must be connected to the power supply that the user has no direct access to the terminal area Outside ...

Page 14: ...door station for that floor and the intercom units that belong to it The floor compact power supply 300091 makes it possible to call direct from the floor door station in the floor line and at the same time direct a call on the main line to an indoor station that is not located in the floor line The floor compact power supply is used whenever there are many door stations on every floor that are co...

Page 15: ...has deactivated the programming mode after the programming time has elapsed Set DIP 2 and 3 back to OFF LED on in ON position The floor compact power supply is in programming mode 4 3 Störung LED Depending on the fault that has occurred the floor compact power supply 300091 will generate a diagnostic error code This is indicated by the Störung LED In case of an error the Störung LED will flash abo...

Page 16: ...nouncement is played back 6 Programming floor intercoms After you have completed the DIP switch settings on the floor compact power supply begin programming the call addresses of the floor indoor stations When the floor compact power supply is in programming mode calls cannot be made from the main line to the floor line Programming can be done two ways The two tables below show the programming pro...

Page 17: ...ed as described in the table below Step Description 1 Set the DIP Switch 2 on the Floor compact power supply to the ON position until the Gespräch HL Prog LED lights up 2 Press the light button on the floor indoor station delete this floor indoor station 3 For each successfully deleted floor indoor station the Gespräch HL Prog LED goes off briefly and the floor indoor station rings 4 If all floor ...

Page 18: ...ax 0 3 A Output rated voltage aEL bEL 24VDC 20 Output rated current aEL bEL max 1A EMV standard safety standard EMV 2014 30 EU EN55032 und EN55024 EG 2014 35 EU EN60950 1 Allgemeines Temperature 5 C up to 45 C Humidity 20 bis 90 non condensing Housing Plastic top hat rail housing Dimensions width x height x depth 105 x 90 x 71 mm 6HP Type IP20 Protection measures Overvoltage and overload protectio...

Page 19: ...SKS Kinkel Elektronik GmbH EN 300091 Floor compact power supply Support Hotline 49 0 2661 98088 112 19 Version 1 3 E Mail support sks kinkel de Document art no 97009603 10 Structure plan 2 wire Audio ...

Page 20: ...SKS Kinkel Elektronik GmbH EN 300091 Floor compact power supply Support Hotline 49 0 2661 98088 112 20 Version 1 3 E Mail support sks kinkel de Document art no 97009603 11 Wiring plan 2 wire audio ...

Page 21: ...SKS Kinkel Elektronik GmbH EN 300091 Floor compact power supply Support Hotline 49 0 2661 98088 112 21 Version 1 3 E Mail support sks kinkel de Document art no 97009603 12 Structure plan 6 wire video ...

Page 22: ...SKS Kinkel Elektronik GmbH EN 300091 Floor compact power supply Support Hotline 49 0 2661 98088 112 22 Version 1 3 E Mail support sks kinkel de Document art no 97009603 13 Wiring plan 6 wire video ...

Page 23: ...n EU guideline 2012 19 EU WEEE and 2011 65 EU RoHS EU REACH regulation and the law implementing regulation EG Nr 1907 2006 Liability disclaimer We have checked the content of this document to verify that it corresponds to the hard and software described herein There may however be deviations and SKS Kinkel GmbH may not be held liable for a lack of conformity The information in this document is che...

Page 24: ...support sks kinkel de Dokument Art Nr 97009603 15 Anhang appendix DIP Schaltereinstellungen für Innensprechstellen Schaltaktor und TK Adapter DIP Switch settings for intercoms switch actuator and TK Adapter Standard Rufadressbereich Erweiterter Rufadressbereich Standard call address range Extended call address range ...

Reviews: