SKS-Kinkel Elektronik GmbH
300092 Extended video compact power supply
EN
Support Hotline: +49 (0) 2661 98088-112
Support E-Mail: support@sks-kinkel.de
Version No. 2-0
Document No. 97009701
20
4 Signalling
LED
Description
Betrieb/Power
Indicates that the device is ready for use
Mitsehsperre aktiv
Indicates that the video privacy function is active
Störung
Indicates that a fault has occurred
4.1
Betrieb/Power LED
The power LED shows the operation status of the Extended Video compact power supply 300092:
LED Status
Description
LED on
The device is ready for use
LED flashing
Supply voltage inside the compact power supply is too low
LED off
Outputs are switched off
4.2
Mitsehsperre aktiv LED (Privacy function LED)
The privacy function guarantees that the video image can only be displayed at the video indoor station which was
called before. The privacy function LED shows the actual status of the privacy function as described in the table
below.
LED Status
Description
LED on
Privacy function active
LED off
Privacy function off
4.3
Störungs-LED (Fault LED)
The Extended video compact power supply 300092 generates a fault code, depending on the fault occurring. This
fault code is signalled by various flashing intervals of the fault LED.
When a fault occurs the fault LED flashes once per second. Here the frequency of the flashing shows the kind of fault
(s. next table). If e. g. the total current is temporarily too high, the LED flashes 4 x once per second and switches off
for 5 seconds afterwards, before it starts flashing again 4 x once per second and so on.
Frequency of flashing
Description
1 x
Internal voltage error
2 x
Overload at +22 output
3 x
Device is overloaded, device temperature is too high
4 x
Short/short-term overload
5 x
Short/long-term overload
6 x
Short/overload at camera output (K 1-4)
7 x
Overload at 12 V output (camera heating/active distributor)
8 x
Short at 12 V output (camera heating/active distributor)
If a fault is recognized the outputs are switched off for 30 seconds, which is indicated by LED 1 (power) switching off.
If faults occur more than once the outputs are switched off for 6 minutes. The most recently detected fault is signalled
for a full day by the fault LED.